RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      납착방법에 따른 임플란트 지지 보철물의 정확성 = The Accuracy of Implant Supported Prosthesis According to Soldering Method

      한글로보기

      https://www.riss.kr/link?id=A30074795

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The Purpose of this study was to measure and compare the gap distance between implant fixture and implant framework fabricated by three techniques; (1) one-piece casting technique. (2) at the same time soldering technique after casting. (3) at t...

      The Purpose of this study was to measure and compare the gap distance between implant fixture and implant framework fabricated by three techniques; (1) one-piece casting technique. (2) at the same time soldering technique after casting. (3) at the different time soldering technique after casting.
      Four 3i (diameter 4.0 ㎜) implant fixtures were fixed in the stone block. Implant bar framework was completed with type 111 gold alloys after it was waxed up with wax sleeve. Implant bar framework was soldered after it was cut with 0.2 ㎜ gap distance and fixed with pattern resin. Gap distances between each implant fixture and abutment, each gap distances were measured by means of stereomicroscope and micrometer ruler.
      The results were as follows :
      1. In comparison of gap distance between implant fixture and abutment, one-piece casting technique group was 531 ㎛, soldering at the same time group was 250 ㎛,soldering at the different time group was 46 ㎛. Therefore, marginal adaptation of soldering technique group was higher than one-piece casting technique group. And marginal adaptation of soldering at the different time technique was higher than soldering at the same time technique.
      2. In comparison of distance between abutment and abutment, one-piece casting technique group was 44.100 ㎜, soldering at the same time technique was 44.064 ㎜, soldering at the different time was 44.059 ㎜ and there were not significant differences.

      더보기

      목차 (Table of Contents)

      • ABSTRACT
      • Ⅰ. 서론
      • Ⅱ. 본론
      • Ⅲ. 증례
      • Ⅳ. 결론
      • ABSTRACT
      • Ⅰ. 서론
      • Ⅱ. 본론
      • Ⅲ. 증례
      • Ⅳ. 결론
      • REFERENCE
      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼