The application of the ultrasonic atomization has been extended because of its good merits. Influx, liquid load, and physical properties are the effecting factors to the size of spray droplets. In this study, distilled water and city water are selecte...
The application of the ultrasonic atomization has been extended because of its good merits. Influx, liquid load, and physical properties are the effecting factors to the size of spray droplets. In this study, distilled water and city water are selected as reference liquids and gasoline, kerosene, and petroleum as fuel liquids. Characteristics and affinity to get the maximum effect for the ultrasonic atomization are observed by using the two ultrasonic transducers with 28KHz and 2MHz.<br/>
Results show that the size distributions of liquid spray droplet by direct vibration method prevail over the aerosol method in uniform droplet size and as a whole, liquid droplet sizes and spray quantum are decreasing according to the head increasing.<br/>