The characteristics of $Co^{2+}$ removal in the kaolinite column were analyzed by electrokinetic remediation. Ethanoic buffer was injected in the kaolinite column and $CH_3$COOH was continuously added to the cathode reservoir to restrain the pH increa...
The characteristics of $Co^{2+}$ removal in the kaolinite column were analyzed by electrokinetic remediation. Ethanoic buffer was injected in the kaolinite column and $CH_3$COOH was continuously added to the cathode reservoir to restrain the pH increase. The pH of the cathode of the kaolinite column was 4.0 at first. Since it was controlled to be under 6.5 after 43.6 hours due to ethanoic buffer, precipitation of ${Co(OH)}_2$ was not formed in the column. Effluent rate increased with time and $Co^{2+}$ removal in the column at initial time was mainly controlled by ion migration. 13.1% of total $Co^{2+}$ in the column was removed after 10 hours, the 46.8% of total $Co^{2+}$ after 20.8 hours, and the 71.7% of total $Co^{2+}$ after 30.1 hours, the 94.6% of total $Co^{2+}$ after 43.6 hours, Meanwhile, the residual concentrations in the column calculated by the developed model were similar to experiment results.