      Transfer Matrix of Curved Duct Bends and Sound Attenuation in Curved Expansion Chambers

      한글로보기

      https://www.riss.kr/link?id=E807307

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      An explicit formula of the transfer matrix is derived for evaluating the acoustic performance of the chamber including curved duct bends. Based on the derived transfer matrix, the reactive sound attenuation of the chamber can be easily calculated by using an empirical formula for estimating the normalized maximum radial pressure of the fundamental mode in the curved duct bend. Predicted results are compared with experimental ones and they show good agreements. It is found that the classical plane wave theory for the straight duct of equivalent length to the curved duct bend is not applicable if the normalized maximum pressure is greater than 1.3. In addition, the sound attenuation in curved expansion chamber is investigated by studying the effect of geometrical parameters. The derived transfer matrix for the curved duct bend can be easily incorporated as a basic module into any existing computer programs dealing with four-pole parameters for predicting the acoustic performance of HVAC and other silencing systems
      번역하기

      An explicit formula of the transfer matrix is derived for evaluating the acoustic performance of the chamber including curved duct bends. Based on the derived transfer matrix, the reactive sound attenuation of the chamber can be easily calculated by u...

      An explicit formula of the transfer matrix is derived for evaluating the acoustic performance of the chamber including curved duct bends. Based on the derived transfer matrix, the reactive sound attenuation of the chamber can be easily calculated by using an empirical formula for estimating the normalized maximum radial pressure of the fundamental mode in the curved duct bend. Predicted results are compared with experimental ones and they show good agreements. It is found that the classical plane wave theory for the straight duct of equivalent length to the curved duct bend is not applicable if the normalized maximum pressure is greater than 1.3. In addition, the sound attenuation in curved expansion chamber is investigated by studying the effect of geometrical parameters. The derived transfer matrix for the curved duct bend can be easily incorporated as a basic module into any existing computer programs dealing with four-pole parameters for predicting the acoustic performance of HVAC and other silencing systems

      더보기

      목차 (Table of Contents)

      • 1. Introduction
      • 2. Theory
      • 2.1. Formulation and solution
      • 2.2. Transfer matrix
      • 3. Calculations
      • 1. Introduction
      • 2. Theory
      • 2.1. Formulation and solution
      • 2.2. Transfer matrix
      • 3. Calculations
      • 3.1. Angular wave number
      • 3.2. Radial pressure distribution of fundamental mode
      • 4. Experimental and theoretical results
      • 4.1. Comparison with the plane wave straight-duct theory
      • 4.2. Effect of geometrical parameters of the curved expansion chamber
      • 5. Conclusions
      • References