In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Hence, this apparatus can be measure to sonic conductance and critical pressure ratio of pneu...
In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Hence, this apparatus can be measure to sonic conductance and critical pressure ratio of pneumatic components and require less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.