RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      2공 측면 금속판 압박 고 나사를 이용한 안정성 대퇴골 전자간 골절의 치료 = Stable Intertrochanteric Fractures Treated with Sliding Screw and Two Hole Side Plate

      한글로보기

      https://www.riss.kr/link?id=A75593533

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: We wished to evaluate and report the clinical results of the treatment of stable intertrochanteric fractures treated by the sliding screws with two-hole side plate fixation method. Material and Methods: From January 2001 to October 2003, 20 patients had stable intertrochanteric fractures treated by the sliding hip screw with two-hole side plate fixation method. We evaluated the healing time, operative blood loss and time, postoperative ambulatory function, incidence of hardware failure and complications including the amount of collapse. Results: The average time to union was 13 weeks. The average operative blood loss was 0.71 pint, and the operative time was 45 minutes. The average skin incision was 6 cm. The average collapse was 4.1 mm and the angle change of the neck shaft was 1.3°. There wasn`t any hardware failure and all patients had a satisfactory postoperative ambulatory function. Conclusion: The use of sliding hip screw with two-hole side plate produces satisfactory healing, and it results in a relatively low blood loss and short surgical time without any hardware failure.
      번역하기

      Purpose: We wished to evaluate and report the clinical results of the treatment of stable intertrochanteric fractures treated by the sliding screws with two-hole side plate fixation method. Material and Methods: From January 2001 to October 2003, 20 p...

      Purpose: We wished to evaluate and report the clinical results of the treatment of stable intertrochanteric fractures treated by the sliding screws with two-hole side plate fixation method. Material and Methods: From January 2001 to October 2003, 20 patients had stable intertrochanteric fractures treated by the sliding hip screw with two-hole side plate fixation method. We evaluated the healing time, operative blood loss and time, postoperative ambulatory function, incidence of hardware failure and complications including the amount of collapse. Results: The average time to union was 13 weeks. The average operative blood loss was 0.71 pint, and the operative time was 45 minutes. The average skin incision was 6 cm. The average collapse was 4.1 mm and the angle change of the neck shaft was 1.3°. There wasn`t any hardware failure and all patients had a satisfactory postoperative ambulatory function. Conclusion: The use of sliding hip screw with two-hole side plate produces satisfactory healing, and it results in a relatively low blood loss and short surgical time without any hardware failure.

      더보기

      참고문헌 (Reference)

      1 "Trochanteric fractures. A review of 110 casestreated by nail-plate fixation. J Bone Joint Surg" 33-, 192-2041951.

      2 "Treatment of Intertrochanteric Hip Fractures with aCompression Hip Screw and a Nail Plate. J Trauma" 599-603, 1976.

      3 "The sliding decompression screw today’sbest answer for stabilization of intertrochanteric hipfractures. Orthop Clin North America" 507-515, 1980.

      4 "The intertrochanteric fractureof femur in the elderly. J Korean Orthop Assoc" 755-762, 1983.

      5 "The Use of Ender’s Pinsin Extracapsular Fractures of the Hip. J Bone and JointSurg" 63 14-28, 1981.

      6 "Special considerations in management.Orthop Clin North America" 571-583, 1974.

      7 "Result of Intertrochanteric Femur Fractures Treated With a 135-Degree Sliding Screw With a Two- Hole Slide Plate" 13 (13): 5-8, 1999.

      8 "Operative Treatment of the Femur Intertrochanteric Fracture Using the Gamma nail and the Compression Hip Screw" 14 : 166-173, 2001.

      9 "Intertrochanteric fractures of thefemur" 1974.

      10 "Complications of Fixation inIntertrochanteric Fractures. Clin Orthop" 110-119, 1974.

      1 "Trochanteric fractures. A review of 110 casestreated by nail-plate fixation. J Bone Joint Surg" 33-, 192-2041951.

      2 "Treatment of Intertrochanteric Hip Fractures with aCompression Hip Screw and a Nail Plate. J Trauma" 599-603, 1976.

      3 "The sliding decompression screw today’sbest answer for stabilization of intertrochanteric hipfractures. Orthop Clin North America" 507-515, 1980.

      4 "The intertrochanteric fractureof femur in the elderly. J Korean Orthop Assoc" 755-762, 1983.

      5 "The Use of Ender’s Pinsin Extracapsular Fractures of the Hip. J Bone and JointSurg" 63 14-28, 1981.

      6 "Special considerations in management.Orthop Clin North America" 571-583, 1974.

      7 "Result of Intertrochanteric Femur Fractures Treated With a 135-Degree Sliding Screw With a Two- Hole Slide Plate" 13 (13): 5-8, 1999.

      8 "Operative Treatment of the Femur Intertrochanteric Fracture Using the Gamma nail and the Compression Hip Screw" 14 : 166-173, 2001.

      9 "Intertrochanteric fractures of thefemur" 1974.

      10 "Complications of Fixation inIntertrochanteric Fractures. Clin Orthop" 110-119, 1974.

      11 "Comparison Between Ender Nail andCompression Hip Screw in the Treatment ofIntertrochanteric Fracture of Femur. J Korean OrthopAssoc" 375-757, 1987.

      12 "Biomechanical study about difference between stainless steel and titanium dynamic hip screws in peritrochanteric fractures of the femur" 32 : 929-936, 1997.

      13 "Biomechanical Evaluation of the DynamicHip Screw With Two-and Four-Hole Slide Plates." 14 (14): 318-323, 2000.

      14 "A self-adjusting Nail-plate for Fracture aboutthe Hip Joint. J Bone and Joint Surg" 37 1085-1093, 1955.

      15 "A prospective study in geriatric patient" 310 : 150-159, 1995.

      16 "A comparison of fixation with Ender nail and sliding screw plate in intertrochanteric fractures of elderly patients." 12 : 203-211, 1999.

      17 "A Clinical Analysis of Treatment ofIntertrochanteric Fractures between the Fixation withEnder Nail and Sliding Screw Plate. J Korean OrthopAssoc" 605-616, 1986.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2025 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2022-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2012-06-29 학술지명변경 한글명 : 대한고관절학회지 -> Hip and Pelvis
      외국어명 : The Journal of Korean Hip Society -> Hip and Pelvis
      KCI등재
      2012-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2008-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2007-01-01 평가 등재후보 1차 FAIL (등재후보2차) KCI등재후보
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2004-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.04 0.04 0.04
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.05 0.05 0.168 0
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼