With the development of pharmaceutical technology, many new medicines are being developed and marketed by spraying the main ingredient in the coating process to extend the duration of effect and reduce medicine intake, increasing the importance of the...
With the development of pharmaceutical technology, many new medicines are being developed and marketed by spraying the main ingredient in the coating process to extend the duration of effect and reduce medicine intake, increasing the importance of the coating process in the tablet manufacturing process. In order to improve the coating quality of tablets, the spray pump control method was changed from a simple speed control method to a speed control method using a flow meter to spray at a constant flow rate without changing the flow rate due to deformation of the peristaltic pump tube due to long-term spray, and the spray pump flow rate was changed to a speed control method using a flow meter. This thesis presents a design method for a tablet coating spray pump flow control system. Through this study, design, and experiment, it is hoped that when using a Coriolis flow meter used for precise flow control, it will help to check the viscosity of the solution used and optimize the viscosity and spray time. It is hoped that this thesis's design, manufacture, and demonstration tests of the tablet coating process will improve the quality of the tablet coating, reduce the setting time and working time of the coating solution spray parameter, and help human health. * A thesis for the degree of Master in February 2024.