      풍력발전 설비가 전력계통의 전력품질에 미치는 영향

      한글로보기

      https://www.riss.kr/link?id=A102086397

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In this study, we have investigated the effect of the wind power generation facilities on the power quality of interconnected wind power generation system. When the wind power generation facility was connected to the distribution system, whether the wind power generation is under operation or not, voltage variation was increased to 0.34%, peak factor of current was increased to 0.145 and phase difference was increased to 0.6° deviation(2.5 times). Harmonic current % in orders was increased to 29.4%, 14.7% and 3.73% at 3rd, 5th and 9th orders respectively. When the wind power generation facilities were not under operation, harmonic current THD(263.7%) was above the technical criteria of domestic power company(5%) and also, harmonic current % in orders(12.4%, 14.2%, 19.4% and 8.06% at 3rd, 5th, 7th and 9th respectively) were above the technical criteria of domestic power company(below 4% under 11th orders). Therefore, it was confirmed that the wind power generation facility, when it was connected to the existing distribution system, made bad influence on the power qualities.
      번역하기

      In this study, we have investigated the effect of the wind power generation facilities on the power quality of interconnected wind power generation system. When the wind power generation facility was connected to the distribution system, whether the w...

      In this study, we have investigated the effect of the wind power generation facilities on the power quality of interconnected wind power generation system. When the wind power generation facility was connected to the distribution system, whether the wind power generation is under operation or not, voltage variation was increased to 0.34%, peak factor of current was increased to 0.145 and phase difference was increased to 0.6° deviation(2.5 times). Harmonic current % in orders was increased to 29.4%, 14.7% and 3.73% at 3rd, 5th and 9th orders respectively. When the wind power generation facilities were not under operation, harmonic current THD(263.7%) was above the technical criteria of domestic power company(5%) and also, harmonic current % in orders(12.4%, 14.2%, 19.4% and 8.06% at 3rd, 5th, 7th and 9th respectively) were above the technical criteria of domestic power company(below 4% under 11th orders). Therefore, it was confirmed that the wind power generation facility, when it was connected to the existing distribution system, made bad influence on the power qualities.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 측정장치 및 방법
      • 3. 측정 결과
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 측정장치 및 방법
      • 3. 측정 결과
      • 4. 결론
      • References
      더보기

      참고문헌 (Reference)

      1 권동철, "계통연계형 태양광발전 시스템이 계통의 전력품질에 미치는 영향" 한국조명.전기설비학회 26 (26): 52-58, 2012

      2 "The Technological Standard for the Connection in the Distribution Power System of the Distributed Energy Resource"

      3 "The Technical Guideline for the Grid Connection of the Substitution Energy Generation System" Ministry of Commerce, Industry and Energy 2004

      4 "The Electric Power System Reliability and Electricity Quality Maintenance Criteria, Notification of Ministry of Commerce, Industry and Energy, Vol. 2005-11"

      5 "IElectromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications"

      6 "IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power System, IEEE Std 519-1992"

      7 "IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications, IEEE Std 446-1995"

      8 "Business 0100 The Basic Rules and Rates for Electric Service"

      9 "Business 0100 The Basic Rules and Rates for Electric Service"

      1 권동철, "계통연계형 태양광발전 시스템이 계통의 전력품질에 미치는 영향" 한국조명.전기설비학회 26 (26): 52-58, 2012

      2 "The Technological Standard for the Connection in the Distribution Power System of the Distributed Energy Resource"

      3 "The Technical Guideline for the Grid Connection of the Substitution Energy Generation System" Ministry of Commerce, Industry and Energy 2004

      4 "The Electric Power System Reliability and Electricity Quality Maintenance Criteria, Notification of Ministry of Commerce, Industry and Energy, Vol. 2005-11"

      5 "IElectromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications"

      6 "IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power System, IEEE Std 519-1992"

      7 "IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications, IEEE Std 446-1995"

      8 "Business 0100 The Basic Rules and Rates for Electric Service"

      9 "Business 0100 The Basic Rules and Rates for Electric Service"

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2015-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2014-01-08 학술지명변경 외국어명 : 미등록 -> Journal of the Korean Institute of Illuminating and Electrical Installation Engineers KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.17 0.17 0.19
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.18 0.17 0.342 0.05
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼