The purpose of this study is to evaluate the difference in healing of Medpor□ implants of two different thickness (1.5mm and 4.5mm) and the effects of methylprednisolone on the healing process. Light micro-scopic and scanning electron microscopic ex...
The purpose of this study is to evaluate the difference in healing of Medpor□ implants of two different thickness (1.5mm and 4.5mm) and the effects of methylprednisolone on the healing process. Light micro-scopic and scanning electron microscopic examinations, and hardness measurement were made in 100 rats 2, 4, or 8 weeks postoperatively. The 1.5mm thin implants were taken better than the 4.5mm thick implants. The inflammatory responses were reduced after application of methylprednisolone with arrangement and amount of bone matrix deposited being more irregular and reduced in bulk than in the control group. To hasten postoperative healing after Medpor□ implantation, the thinner material should be used and steroid injection should be avoided.
Key Words : Medpor□, methylprednisolone