The CFTA girder has a good advantageous structural system such as reducing the moment by way of arch shape and prestressing force and inducing compressive force to compensate for tensile stress. In this study, Seven steps were to be considered in the ...
The CFTA girder has a good advantageous structural system such as reducing the moment by way of arch shape and prestressing force and inducing compressive force to compensate for tensile stress. In this study, Seven steps were to be considered in the process of construction Sequence analysis. For the test result of construction Sequence analysis, all steps stress of CFTA members are in a permissible range of allowable stress.