RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      류마티스 인자 측정의 가장 우수한 방법은? = What is the Best Method in Measuring Rheumatoid Factors?

      한글로보기

      https://www.riss.kr/link?id=A76550162

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective: Rheumatoid factor (RF) is used as one of the criteria for the diagnosis of rheumatoid arthritis (RA). Nephelometers are widely used in laboratories to quantitatively measure RF. In nephelometric ways of measurement, there are endpoint nephelometry and rate nephelometry. BN II System (BN II) (Dade Behring Marburg GmbH, USA) is a well known endpoint nephelometer while IMMAGE System (IMMAGE) (Beckman Coulter, USA) is a well known rate nephelometer. We compared these two automatic nephelometric analyzers to evaluate which method shows the best results. Methods: We measured RF (n=195) using the two machines. We evaluated the correlation between BN II and IMMAGE. We compared the results of BN II with those of IMMAGE in terms of interference and clinical usefulness. Results: The correlation coefficient (r) of RF was 0.9310 (p<0.0001). We could not find any significant interference for BN II with high concentration of triglyceride or bilirubin, but IMMAGE showed significant interferences with high concentrations of triglyceride and bilirubin. The sensitivity and specificity of BN II for the diagnosis of RA were 90.3% and 82.4%. Those of IMMAGE were 86.1% and 74.5%. Conclusion: BN II was enough to satisfy the analytical features and it showed better results than IMMAGE. We expect BN II, the endpoint nephelometer, to be the best equipment in measuring RF for diagnosis of RA.
      번역하기

      Objective: Rheumatoid factor (RF) is used as one of the criteria for the diagnosis of rheumatoid arthritis (RA). Nephelometers are widely used in laboratories to quantitatively measure RF. In nephelometric ways of measurement, there are endpoint nephe...

      Objective: Rheumatoid factor (RF) is used as one of the criteria for the diagnosis of rheumatoid arthritis (RA). Nephelometers are widely used in laboratories to quantitatively measure RF. In nephelometric ways of measurement, there are endpoint nephelometry and rate nephelometry. BN II System (BN II) (Dade Behring Marburg GmbH, USA) is a well known endpoint nephelometer while IMMAGE System (IMMAGE) (Beckman Coulter, USA) is a well known rate nephelometer. We compared these two automatic nephelometric analyzers to evaluate which method shows the best results. Methods: We measured RF (n=195) using the two machines. We evaluated the correlation between BN II and IMMAGE. We compared the results of BN II with those of IMMAGE in terms of interference and clinical usefulness. Results: The correlation coefficient (r) of RF was 0.9310 (p<0.0001). We could not find any significant interference for BN II with high concentration of triglyceride or bilirubin, but IMMAGE showed significant interferences with high concentrations of triglyceride and bilirubin. The sensitivity and specificity of BN II for the diagnosis of RA were 90.3% and 82.4%. Those of IMMAGE were 86.1% and 74.5%. Conclusion: BN II was enough to satisfy the analytical features and it showed better results than IMMAGE. We expect BN II, the endpoint nephelometer, to be the best equipment in measuring RF for diagnosis of RA.

      더보기

      참고문헌 (Reference)

      1 "면역혈청검사 신빙도조사 결과보고(2003)" 26 : 49-75, 2004

      2 "류마티스 관절염의 면역혈청학적 검사" 35 : 1206-12, 1992

      3 "The effect of reaction temperature for nephelometric assays for rheumatoid factor" 292 : 117-125, 2000

      4 "The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis" 31 : 315-24, 1988

      5 "Test for detection of rheumatoidfactors Manual of clinical labora-tory immunology" 762-4, 1992

      6 "Rheumatoid factors" ASM Press 961-972, 2002

      7 "Rheumatoid factors" 26 : 75-84, 1993

      8 "Rheumatoid factor:its na-ture,specificity,and production in rheumatoid arthritis" 6 : 414-30, 1976

      9 "Results of tests for rheumatoid factor on CAP survey specimens" 80 (80): 599-602, 1983

      10 "Rate nephelometric determination of rheumatoid factor:comparison between Kallestad QM-300 and Beckman ICS-II(RF)methods" 43 : 243-5, 1990

      1 "면역혈청검사 신빙도조사 결과보고(2003)" 26 : 49-75, 2004

      2 "류마티스 관절염의 면역혈청학적 검사" 35 : 1206-12, 1992

      3 "The effect of reaction temperature for nephelometric assays for rheumatoid factor" 292 : 117-125, 2000

      4 "The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis" 31 : 315-24, 1988

      5 "Test for detection of rheumatoidfactors Manual of clinical labora-tory immunology" 762-4, 1992

      6 "Rheumatoid factors" ASM Press 961-972, 2002

      7 "Rheumatoid factors" 26 : 75-84, 1993

      8 "Rheumatoid factor:its na-ture,specificity,and production in rheumatoid arthritis" 6 : 414-30, 1976

      9 "Results of tests for rheumatoid factor on CAP survey specimens" 80 (80): 599-602, 1983

      10 "Rate nephelometric determination of rheumatoid factor:comparison between Kallestad QM-300 and Beckman ICS-II(RF)methods" 43 : 243-5, 1990

      11 "Quantitation of rheumatoid factors by enzyme immunoassay using biotinylated human IgG" 87 : 229-37, 1986

      12 "Prospective study of the early course of rheumatoid arthritis in young adults:comparison of patients with and without rheumatoid factor positivity at entry and identification of variables correlating with outcome" 4 : 299-326, 1976

      13 "Nine rheumatoid factor assays compared" 26 : 863-71, 1988

      14 "International reference preparation of rheumatoid arthritis serum" 42 : 311-8, 1970

      15 "Interference testing in clinical chemistry; Approved guideline" NCCLS document NCCLS-EP7- A 2002

      16 "In vitro effects of Epstein-Barr virus on peripheral blood mononuclear cells from patients with rheumatoid arthritis and normal subjects" 148 : 1429-34, 1978

      17 "In vitro IgM and IgM rheumatoid factor production in response to Staphylococcus aureus Cowan I and pokeweed mitogen:the contribution of CD5(Leu 1)B cells" 77 : 179-83, 1989

      18 "Frequency analysis of human peripheral blood B cells producing IgM- rheumatoid factor.Differential effects of stimulation with monoclonal antibodies to CD3 and Staphylococcus aureus" 145 : 1681-6, 1990

      19 "Evaluation of interferences in rate and fixed-time nephelometric assays of specific serum proteins" 45 : 62-67, 1999

      20 "Evaluation of four automated high-sensitivity C- reactive protein methods:implications for clinical and epidemiological applications" 46 : 461-468, 2000

      21 "Clinical analyzers.Immunoassays" 71 : 356-362, 1999

      22 "Antibody-based methods" ASM Press 6-25, 2002

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2016-03-09 학회명변경 영문명 : The Korean Rheumatism Association -> Korean College of Rheumatology KCI등재
      2015-04-03 학술지명변경 외국어명 : The Journal of the Korean Rheumatism Association -> Journal of Rheumatic Diseases KCI등재
      2015-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2005-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.1 0.1 0.08
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.08 0.09 0.242 0.09
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼