RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      EPID를 이용한 정위적방사선수술의 중심점 검사에 대한 연구 = Isocenter Check and QA of Tactic Radiosurgery Devices Using EPID

      한글로보기

      https://www.riss.kr/link?id=A100841583

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The Winston Lutz test, which checks the accuracy of the isocenter for stereotactic radiosurgery (SRS), was performed with the commercial electronic portal imaging device (EPID). The usual Winston Lutz test with film was also performed for comparison with the test with EPID. The maximum difference in isocenter between the two methods was 0.32 mm. The Winston Lutz test using EPID is practical as it can reduce time and avoid human errors compared to the test with film.
      번역하기

      The Winston Lutz test, which checks the accuracy of the isocenter for stereotactic radiosurgery (SRS), was performed with the commercial electronic portal imaging device (EPID). The usual Winston Lutz test with film was also performed for comparison w...

      The Winston Lutz test, which checks the accuracy of the isocenter for stereotactic radiosurgery (SRS), was performed with the commercial electronic portal imaging device (EPID). The usual Winston Lutz test with film was also performed for comparison with the test with EPID. The maximum difference in isocenter between the two methods was 0.32 mm. The Winston Lutz test using EPID is practical as it can reduce time and avoid human errors compared to the test with film.

      더보기

      참고문헌 (Reference)

      1 Leksell L, "The stereotaxic method and radiosurgery of the brain" 102 (102): 316-319, 1951

      2 Zheng C, "Six degree-of-freedom image guidance for frameless intra-cranial stereotactic radiosurgery with kilo-voltage cone-beam CT" 1 (1): 2010

      3 E. Shaw, "Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: Final report of RTOG protocol 90-05" 47 : 291-298, 2000

      4 Podgorsak EB, "Radiosurgery with photon beams: physical aspects and adequacy of linear accelerators" 17 (17): 349-358, 1990

      5 Podgorsak EB, "Radiosurgery with high energy photon beams: a comparison among techniques" 16 (16): 857-865, 1989

      6 Serago ChF, "Radiosurgery target point alignment errors detected with portal film verification" 24 (24): 777-780, 1992

      7 Pejman Rowshanfarzad, "Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques" 12 (12): 2011

      8 H. Shirato, "Fractionated stereotactic radiotherapy for vestibular schwannoma (vs):Comparison between cystic-type and solid-type vs" 48 : 1395-1401, 2000

      9 J.A. Williams, "Fractionated stereotactic radiotherapy for acoustic neuromas" 54 : 500-504, 2002

      10 L. Walton, "Development of a relocatable frame technique for gamma knife radiosurgery:Technical note" 93 : 198-202, 2000

      1 Leksell L, "The stereotaxic method and radiosurgery of the brain" 102 (102): 316-319, 1951

      2 Zheng C, "Six degree-of-freedom image guidance for frameless intra-cranial stereotactic radiosurgery with kilo-voltage cone-beam CT" 1 (1): 2010

      3 E. Shaw, "Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: Final report of RTOG protocol 90-05" 47 : 291-298, 2000

      4 Podgorsak EB, "Radiosurgery with photon beams: physical aspects and adequacy of linear accelerators" 17 (17): 349-358, 1990

      5 Podgorsak EB, "Radiosurgery with high energy photon beams: a comparison among techniques" 16 (16): 857-865, 1989

      6 Serago ChF, "Radiosurgery target point alignment errors detected with portal film verification" 24 (24): 777-780, 1992

      7 Pejman Rowshanfarzad, "Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques" 12 (12): 2011

      8 H. Shirato, "Fractionated stereotactic radiotherapy for vestibular schwannoma (vs):Comparison between cystic-type and solid-type vs" 48 : 1395-1401, 2000

      9 J.A. Williams, "Fractionated stereotactic radiotherapy for acoustic neuromas" 54 : 500-504, 2002

      10 L. Walton, "Development of a relocatable frame technique for gamma knife radiosurgery:Technical note" 93 : 198-202, 2000

      11 Ramaseshan R, "Comprehensive quality assurance for stereotactic radiosurgery treatments" 48 (48): N199-N205, 2003

      12 Verellen D, "Assessment of the uncertainties in dose delivery of a commercial system for linac-based stereotactic radiosurgery" 44 (44): 421-433, 1999

      13 Lutz W, "A system for stereotactic radiosurgery with a linear accelerator" 14 (14): 373-381, 1988

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2019-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2016-12-01 평가 등재후보 탈락 (계속평가)
      2015-12-01 평가 등재후보로 하락 (기타) KCI등재후보
      2014-07-10 학술지명변경 외국어명 : Korean Journal of Medical Physics -> PROGRESS in MEDICAL PHYSICS KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2006-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2005-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼