    KCI등재

    3차원 안면자동인식기(3D-AFRA)의 Software 정밀도 검사 : 형상측정프로그램 오차분석 = A Software Error Examination of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Measurement of Facial Figure Data

    한글로보기

    https://www.riss.kr/link?id=A101482448

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    1. Objectives The Face is an important standard for the classification of Sasang Constitutions. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So We should examine the Measurement of Facial Figure data error of 3D Automatic Face Recognition Apparatus(3D-AFRA) in Software Error Analysis. 2. Methods We scanned face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And we measured lengths Between Facial Definition Parameters of facial figure data by Facial Measurement program. 2.1 Repeatability test We measured lengths Between Facial Definition Parameters of facial figure data restored by 3D-AFRA by Facial Measurement program 10 times. Then we compared 10 results each other for repeatability test. 2.2 Measurement error test We measured lengths Between Facial Definition Parameters of facial figure data by two different measurement program that are Facial Measurement program and Rapidform2006. At measuring lengths Between Facial Definition Parameters, we uses two measurement way. The one is straight line measurement, the other is curved line measurement. Then we compared results measured by Facial Measurement program with results measured by Rapidform2006. 3. Results and Conclusions In repeatability test, standard deviation of results is 0.084-0.450mm. And in straight line measurement error test, the average error 0.0582mm, and the maximum error was 0.28mm. In curved line measurement error test, the average error 0.413mm, and the maximum error was 1.53mm. In conclusion, we assessed that the accuracy and repeatability of Facial Measurement program is considerably good. From now on we complement accuracy of 3D-AFRA in Hardware and Software.
    번역하기

    1. Objectives The Face is an important standard for the classification of Sasang Constitutions. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's...

    1. Objectives The Face is an important standard for the classification of Sasang Constitutions. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So We should examine the Measurement of Facial Figure data error of 3D Automatic Face Recognition Apparatus(3D-AFRA) in Software Error Analysis. 2. Methods We scanned face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And we measured lengths Between Facial Definition Parameters of facial figure data by Facial Measurement program. 2.1 Repeatability test We measured lengths Between Facial Definition Parameters of facial figure data restored by 3D-AFRA by Facial Measurement program 10 times. Then we compared 10 results each other for repeatability test. 2.2 Measurement error test We measured lengths Between Facial Definition Parameters of facial figure data by two different measurement program that are Facial Measurement program and Rapidform2006. At measuring lengths Between Facial Definition Parameters, we uses two measurement way. The one is straight line measurement, the other is curved line measurement. Then we compared results measured by Facial Measurement program with results measured by Rapidform2006. 3. Results and Conclusions In repeatability test, standard deviation of results is 0.084-0.450mm. And in straight line measurement error test, the average error 0.0582mm, and the maximum error was 0.28mm. In curved line measurement error test, the average error 0.413mm, and the maximum error was 1.53mm. In conclusion, we assessed that the accuracy and repeatability of Facial Measurement program is considerably good. From now on we complement accuracy of 3D-AFRA in Hardware and Software.

    더보기

    참고문헌 (Reference)

    1 "한국인 남자 30~40대와 50~60대의 사상체질별 안면형태에 관한 비교 연구" 12 (12): 143-152, 2000

    2 "한국인 남녀 50~60대의 사상체질별 안면형태에 관한 표준화 연구" 12 (12): 23-131, 2000

    3 "태음인과 소음인의 두면부의 체질인류학특점" 9 (9): 299-302, 1997

    4 "사상체질진단의 객관화를 위한 형태학적 연구-소음인의 형태학적 특징" 10 (10): 171-180, 1998

    5 "사상체질병 두면부의 형태학적 특징" 8 (8): 101-186, 1996

    6 "사상체질별 상안부의 형태학적 연구-모아레횡단면의 특성을 중심으로" 10 (10): 161-170, 1998

    7 "사상체질별 상안부 Moire형태의 특징에 관한 연구" 10 (10): 271-282, 1998

    8 "사상인 이목비구의 형태학적 특징 연구" 10 (10): 221-270, 1998

    9 "사상인 용모의 두면계측 표준화 연구" 2007

    10 "사상인 용모분석을 위한 얼굴표준 및 얼굴유형에 대한 연구현황" 18 (18): 25-33, 2006

    1 "한국인 남자 30~40대와 50~60대의 사상체질별 안면형태에 관한 비교 연구" 12 (12): 143-152, 2000

    2 "한국인 남녀 50~60대의 사상체질별 안면형태에 관한 표준화 연구" 12 (12): 23-131, 2000

    3 "태음인과 소음인의 두면부의 체질인류학특점" 9 (9): 299-302, 1997

    4 "사상체질진단의 객관화를 위한 형태학적 연구-소음인의 형태학적 특징" 10 (10): 171-180, 1998

    5 "사상체질병 두면부의 형태학적 특징" 8 (8): 101-186, 1996

    6 "사상체질별 상안부의 형태학적 연구-모아레횡단면의 특성을 중심으로" 10 (10): 161-170, 1998

    7 "사상체질별 상안부 Moire형태의 특징에 관한 연구" 10 (10): 271-282, 1998

    8 "사상인 이목비구의 형태학적 특징 연구" 10 (10): 221-270, 1998

    9 "사상인 용모의 두면계측 표준화 연구" 2007

    10 "사상인 용모분석을 위한 얼굴표준 및 얼굴유형에 대한 연구현황" 18 (18): 25-33, 2006

    11 "The support of the Office of Naval Research"

    12 "3차원 인체형상 계측기의 정확도 및 신뢰도 개발" 산업자원부 148-, 2002

    13 "3차원 안면자동인식기의 형상복원 오차검사" 18 (18): 41-49, 2006

    14 "3차원 안면자동인식기의 표준안 제안" 2007

    15 "3차원 안면자동인식기의 안면 위치변화에 따른 정확도 검사" 18 (18): 57-63, 2006

    16 "3차원 안면자동인식기의 Positioning 오차분석" 18 (18): 34-40, 2006

    17 "3차원 안면자동인식기의 Hardware 오차분석" 18 (18): 49-56, 2006

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2022 평가 재인증평가 신청대상 (재인증)
    2019-01-01 등재 등재학술지 유지 (계속평가) KCI등재
    2016-01-01 등재 등재학술지 선정 (계속평가) KCI등재
    2015-12-01 등재 등재후보로 하락 (기타) KCI등재후보
    2011-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2008-01-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2007-01-01 등재 등재후보 1차 PASS (등재후보1차) KCI등재후보
    2005-01-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 1.05 1.05 0.99
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    1.02 0.91 0.778 0.11
    더보기
    해외이동버튼