      3차원 안면자동분석 사상체질진단기의 Hardware 오차분석 = An Error Analysis of the 3D Automatic Face Recognition Apparatus (3D-AFRA) Hardware

      한글로보기

      https://www.riss.kr/link?id=A101482445

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      1. Objectives Sasang Contitutional Medicine, a part of the traditional Korean medical lore, treats illness through a constitutional typing system that categorizespeople into four constitutional types. A few of the important criteria for differentiating the constitutional types are external appearances, inner state of mind, and pathological patterns. We had been developing a 3D Automatic Face Recognition Apparatus (3D-AFRA) in order to evaluate the external appearances with more objectivity. This apparatus provides a 3D image and numerical data on facial configuration, and this study aims to evaluate the mechanical accuracy of the 3D-AFRA hardware. 2. Methods Several objects of different shapes (cube, cylinder, cone, pyramid) were each scanned 10 times using the 3D Automatic Face Recognition Apparatus (3D-AFRA). The results were then compared and analyzed with data retrieved through a laser scanner known for its high accuracy. The error rates were analyzed for each grid point of facial contour scanned with Rapidform2006 (Rapidform2006 is a 3D scanning software that collects grid point data for contours of various products and products and product parts through 3D scanners and other 3D measuring devices; the grid point data thusly acquired is then used to reconstruct highly precise polygon and curvature models). 3. Results and Conclusions The average error rate was 0.22mm for the cube, 0.22mm for the cylinder, 0.125mm for the cone, and 0.172mm for the pyramid. The visual data comparing error rates for measurement figures retrieved with Rapidform2006 is shown in $Fig.3{\sim}Fig.6$. Blue tendency indicates smaller error rates, while red indicates greater error rates The protruding corners of the cube display red, indicating greater error rates. The cylinder shows greater error rates on the edges. The pyramid displays greater error rates on the base surface and around the vertex. The cone also shows greater error around the protruding edge.
      번역하기

      1. Objectives Sasang Contitutional Medicine, a part of the traditional Korean medical lore, treats illness through a constitutional typing system that categorizespeople into four constitutional types. A few of the important criteria for differentiatin...

      1. Objectives Sasang Contitutional Medicine, a part of the traditional Korean medical lore, treats illness through a constitutional typing system that categorizespeople into four constitutional types. A few of the important criteria for differentiating the constitutional types are external appearances, inner state of mind, and pathological patterns. We had been developing a 3D Automatic Face Recognition Apparatus (3D-AFRA) in order to evaluate the external appearances with more objectivity. This apparatus provides a 3D image and numerical data on facial configuration, and this study aims to evaluate the mechanical accuracy of the 3D-AFRA hardware. 2. Methods Several objects of different shapes (cube, cylinder, cone, pyramid) were each scanned 10 times using the 3D Automatic Face Recognition Apparatus (3D-AFRA). The results were then compared and analyzed with data retrieved through a laser scanner known for its high accuracy. The error rates were analyzed for each grid point of facial contour scanned with Rapidform2006 (Rapidform2006 is a 3D scanning software that collects grid point data for contours of various products and products and product parts through 3D scanners and other 3D measuring devices; the grid point data thusly acquired is then used to reconstruct highly precise polygon and curvature models). 3. Results and Conclusions The average error rate was 0.22mm for the cube, 0.22mm for the cylinder, 0.125mm for the cone, and 0.172mm for the pyramid. The visual data comparing error rates for measurement figures retrieved with Rapidform2006 is shown in $Fig.3{\sim}Fig.6$. Blue tendency indicates smaller error rates, while red indicates greater error rates The protruding corners of the cube display red, indicating greater error rates. The cylinder shows greater error rates on the edges. The pyramid displays greater error rates on the base surface and around the vertex. The cone also shows greater error around the protruding edge.

      더보기

      참고문헌 (Reference)

      1 "한국인 남자 30~40대와 50~60대의 사상체질별 안면형태에 관한 비교 연구" 12 (12): 143-152, 2000

      2 "한국인 남녀 50~60대의 사상체질별 안면형태에 관한 표준화 연구" 12 (12): 123-131, 2000

      3 "차원 안면자동인식기의 형상복원 오차검사" 18 (18): 41-49, 2006

      4 "이제마의 형상관 이해와 안면부 형태의 해석" 11 (11): 311-327, 1999

      5 "사상체질별 상안부의 형태학적인 특징에 관한 연구-모아레의 횡단면의 특성을 중심으로" 10 (10): 161-170, 1998

      6 "사상체질별 상안부 Moire형태의 특징에 관한 연구" 10 (10): 271-281, 1998

      7 "사상인의 용모에 관한 설문분석 연구" 27 (27): 130-137, 2006

      8 "사상인의 용모에 관한 문헌적 연구" 17 (17): 55-68, 2005

      9 "사상인 이목비구의 형태학적 특징 연구" 10 (10): 221-270, 1998

      10 "사상인 용모분석을 위한 얼굴표준 및 얼굴유형에 대한 연구현황" 18 (18): 25-33, 2006

      1 "한국인 남자 30~40대와 50~60대의 사상체질별 안면형태에 관한 비교 연구" 12 (12): 143-152, 2000

      2 "한국인 남녀 50~60대의 사상체질별 안면형태에 관한 표준화 연구" 12 (12): 123-131, 2000

      3 "차원 안면자동인식기의 형상복원 오차검사" 18 (18): 41-49, 2006

      4 "이제마의 형상관 이해와 안면부 형태의 해석" 11 (11): 311-327, 1999

      5 "사상체질별 상안부의 형태학적인 특징에 관한 연구-모아레의 횡단면의 특성을 중심으로" 10 (10): 161-170, 1998

      6 "사상체질별 상안부 Moire형태의 특징에 관한 연구" 10 (10): 271-281, 1998

      7 "사상인의 용모에 관한 설문분석 연구" 27 (27): 130-137, 2006

      8 "사상인의 용모에 관한 문헌적 연구" 17 (17): 55-68, 2005

      9 "사상인 이목비구의 형태학적 특징 연구" 10 (10): 221-270, 1998

      10 "사상인 용모분석을 위한 얼굴표준 및 얼굴유형에 대한 연구현황" 18 (18): 25-33, 2006

      11 "동의수세보원. 사상의학회간행" 대성문화사, 서울 1998

      12 "3차원 안면자동인식기의 안면 위치변화에 따른 정확도 검사" 18 (18): 57-63, 2006

      13 "3차원 안면자동인식기의 Positioning 오차분석" 18 (18): 34-40, 2006

      14 "3차원 안면자동인식기의 Hardware 오차분석" 18 (18): 49-56, 2006

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2022 평가예정 재인증평가 신청대상 (재인증)
      2019-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2015-12-01 평가 등재후보로 하락 (기타) KCI등재후보
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2007-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.05 1.05 0.99
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      1.02 0.91 0.778 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼