RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재 SCIE SCOPUS

    Staging of Hepatic Fibrosis: Comparison of Magnetic Resonance Elastography and Shear Wave Elastography in the Same Individuals

    한글로보기

    https://www.riss.kr/link?id=A103914116

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Objective: To cross-validate liver stiffness (LS) measured on shear wave elastography (SWE) and on magnetic resonance elastography (MRE) in the same individuals.
    Materials and Methods: We included 94 liver transplantation (LT) recipients and 114 liver donors who underwent either MRE or SWE before surgery or biopsy. We determined the technical success rates and the incidence of unreliable LS measurements (LSM) of SWE and MRE. Among the 69 patients who underwent both MRE and SWE, the median and coefficient of variation (CV) of the LSM from each examination were compared and correlated. Areas under the receiver operating characteristic curve in both examinations were calculated in order to exclude the presence of hepatic fibrosis (HF).
    Results: The technical success rates of MRE and SWE were 96.4% and 92.2%, respectively (p = 0.17), and all of the technical failures occurred in LT recipients. SWE showed 13.1% unreliable LSM, whereas MRE showed no such case (p < 0.05). There was moderate correlation in the LSM in both examinations (r = 0.67). SWE showed a significantly larger median LSM and CV than MRE. Both examinations showed similar diagnostic performance for excluding HF (Az; 0.989, 1.000, respectively).
    Conclusion: MRE and SWE show moderate correlation in their LSMs, although SWE shows higher incidence of unreliable LSMs in cirrhotic liver.
    번역하기

    Objective: To cross-validate liver stiffness (LS) measured on shear wave elastography (SWE) and on magnetic resonance elastography (MRE) in the same individuals. Materials and Methods: We included 94 liver transplantation (LT) recipients and 114 liver...

    Objective: To cross-validate liver stiffness (LS) measured on shear wave elastography (SWE) and on magnetic resonance elastography (MRE) in the same individuals.
    Materials and Methods: We included 94 liver transplantation (LT) recipients and 114 liver donors who underwent either MRE or SWE before surgery or biopsy. We determined the technical success rates and the incidence of unreliable LS measurements (LSM) of SWE and MRE. Among the 69 patients who underwent both MRE and SWE, the median and coefficient of variation (CV) of the LSM from each examination were compared and correlated. Areas under the receiver operating characteristic curve in both examinations were calculated in order to exclude the presence of hepatic fibrosis (HF).
    Results: The technical success rates of MRE and SWE were 96.4% and 92.2%, respectively (p = 0.17), and all of the technical failures occurred in LT recipients. SWE showed 13.1% unreliable LSM, whereas MRE showed no such case (p < 0.05). There was moderate correlation in the LSM in both examinations (r = 0.67). SWE showed a significantly larger median LSM and CV than MRE. Both examinations showed similar diagnostic performance for excluding HF (Az; 0.989, 1.000, respectively).
    Conclusion: MRE and SWE show moderate correlation in their LSMs, although SWE shows higher incidence of unreliable LSMs in cirrhotic liver.

    더보기

    참고문헌 (Reference)

    1 Ferraioli G, "on behalf of the Liver Fibrosis Study Group. Accuracy of realtime shear wave elastography for assessing liver fibrosis in chronic hepatitis C: A pilot study" 56 : 2125-2133, 2012

    2 Euser AM, "le Cessie S. A practical approach to Bland-Altman plots and variation coefficients for log transformed variables" 61 : 978-982, 2008

    3 Asbach P, "Viscoelasticity-based staging of hepatic fibrosis with multifrequency MR elastography" 257 : 80-86, 2010

    4 "The accuracy of noninvasive methods in predicting the development of hepatocellular carcinoma and hepatic decompensation in patients with chronic hepatitis B" LIPPINCOTT WILLIAMS & WILKINS 46 (46): 518-525, 2012

    5 Bercoff J, "Supersonic shear imaging: a new technique for soft tissue elasticity mapping" 51 : 396-409, 2004

    6 Ferraioli G, "Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity" 81 : 3102-3106, 2012

    7 Hines CD, "Repeatability of magnetic resonance elastography for quantification of hepatic stiffness" 31 : 725-731, 2010

    8 Tanter M, "Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging" 34 : 1373-1386, 2008

    9 Masuzaki R, "Prospective risk assessment for hepatocellular carcinoma development in patients with chronic hepatitis C by transient elastography" 49 : 1954-1961, 2009

    10 Fung J, "Prognostic significance of liver stiffness for hepatocellular carcinoma and mortality in HBeAg-negative chronic hepatitis B" 18 : 738-744, 2011

    1 Ferraioli G, "on behalf of the Liver Fibrosis Study Group. Accuracy of realtime shear wave elastography for assessing liver fibrosis in chronic hepatitis C: A pilot study" 56 : 2125-2133, 2012

    2 Euser AM, "le Cessie S. A practical approach to Bland-Altman plots and variation coefficients for log transformed variables" 61 : 978-982, 2008

    3 Asbach P, "Viscoelasticity-based staging of hepatic fibrosis with multifrequency MR elastography" 257 : 80-86, 2010

    4 "The accuracy of noninvasive methods in predicting the development of hepatocellular carcinoma and hepatic decompensation in patients with chronic hepatitis B" LIPPINCOTT WILLIAMS & WILKINS 46 (46): 518-525, 2012

    5 Bercoff J, "Supersonic shear imaging: a new technique for soft tissue elasticity mapping" 51 : 396-409, 2004

    6 Ferraioli G, "Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity" 81 : 3102-3106, 2012

    7 Hines CD, "Repeatability of magnetic resonance elastography for quantification of hepatic stiffness" 31 : 725-731, 2010

    8 Tanter M, "Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging" 34 : 1373-1386, 2008

    9 Masuzaki R, "Prospective risk assessment for hepatocellular carcinoma development in patients with chronic hepatitis C by transient elastography" 49 : 1954-1961, 2009

    10 Fung J, "Prognostic significance of liver stiffness for hepatocellular carcinoma and mortality in HBeAg-negative chronic hepatitis B" 18 : 738-744, 2011

    11 Castéra L, "Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations" 51 : 828-835, 2010

    12 Friedrich-Rust M, "Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis" 19 : e212-e219, 2012

    13 Nariya Cho, "Nonpalpable Breast Masses: Evaluation by US Elastography" 대한영상의학회 9 (9): 111-118, 2008

    14 Castera L, "Noninvasive methods to assess liver disease in patients with hepatitis B or C" 142 : 1293-1302, 2012

    15 Bavu E, "Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients" 37 : 1361-1373, 2011

    16 Rockey DC, "Noninvasive assessment of liver fibrosis and portal hypertension with transient elastography" 134 : 8-14, 2008

    17 Tsochatzis EA, "New therapeutic paradigm for patients with cirrhosis" 56 : 1983-1992, 2012

    18 Yoon KT, "New diagnostic method for liver fibrosis and cirrhosis" 51 : 11-16, 2008

    19 Palle Lalitha, "Musculoskeletal Applications of Elastography: a Pictorial Essay of Our Initial Experience" 대한영상의학회 12 (12): 365-375, 2011

    20 Bensamoun SF, "Measurement of liver stiffness with two imaging techniques: magnetic resonance elastography and ultrasound elastometry" 28 : 1287-1292, 2008

    21 Manduca A, "Magnetic resonance elastography: non-invasive mapping of tissue elasticity" 5 : 237-254, 2001

    22 Mariappan YK, "Magnetic resonance elastography: a review" 23 : 497-511, 2010

    23 Huwart L, "Magnetic resonance elastography for the noninvasive staging of liver fibrosis" 135 : 32-40, 2008

    24 Faria SC, "MR imaging of liver fibrosis: current state of the art" 29 : 1615-1635, 2009

    25 Rouvière O, "MR elastography of the liver: preliminary results" 240 : 440-448, 2006

    26 Venkatesh SK, "MR elastography of liver tumors: preliminary results" 190 : 1534-1540, 2008

    27 Lee DH, "MR elastography of healthy liver parenchyma: Normal value and reliability of the liver stiffness value measurement" 2012

    28 Kim BH, "MR elastography for noninvasive assessment of hepatic fibrosis: experience from a tertiary center in Asia" 34 : 1110-1116, 2011

    29 Carrión JA, "Liver stiffness identifies two different patterns of fibrosis progression in patients with hepatitis C virus recurrence after liver transplantation" 51 : 23-34, 2010

    30 Robic MA, "Liver stiffness accurately predicts portal hypertension related complications in patients with chronic liver disease: a prospective study" 55 : 1017-1024, 2011

    31 Huwart L, "Liver fibrosis: noninvasive assessment with MR elastography versus aspartate aminotransferase-to-platelet ratio index" 245 : 458-466, 2007

    32 Huwart L, "Liver fibrosis: non-invasive assessment with MR elastography" 19 : 173-179, 2006

    33 Friedman SL, "Liver fibrosis -- from bench to bedside" 38 (38): S38-S53, 2003

    34 Van Thiel DH, "Liver biopsy. Its safety and complications as seen at a liver transplant center" 55 : 1087-1090, 1993

    35 Bravo AA, "Liver biopsy" 344 : 495-500, 2001

    36 Castera L, "Invasive and non-invasive methods for the assessment of fibrosis and disease progression in chronic liver disease" 25 : 291-303, 2011

    37 "Intraobserver and interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C" The French METAVIR Cooperative Study Group 20 (20): 15-20, 1994

    38 Myers RP, "Feasibility and diagnostic performance of the FibroScan XL probe for liver stiffness measurement in overweight and obese patients" 55 : 199-208, 2012

    39 Rzymski P, "Factors influencing breast elasticity measured by the ultrasound Shear Wave elastography - preliminary results" 7 : 127-133, 2011

    40 Tsochatzis EA, "Elastography for the diagnosis of severity of fibrosis in chronic liver disease: a meta-analysis of diagnostic accuracy" 54 : 650-659, 2011

    41 전영욱, "Dynamic CT Perfusion Imaging for the Detection of Crossed Cerebellar Diaschisis in Acute Ischemic Stroke" 대한영상의학회 13 (13): 12-19, 2012

    42 Tang A, "Does hepatic vein transit time performed with contrastenhanced ultrasound predict the severity of hepatic fibrosis?" 37 : 1963-1969, 2011

    43 Myers RP, "Discordance in fibrosis staging between liver biopsy and transient elastography using the FibroScan XL probe" 56 : 564-570, 2012

    44 Bonekamp S, "Diffusion-weighted magnetic resonance imaging for the staging of liver fibrosis" 45 : 885-892, 2011

    45 Foucher J, "Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study" 55 : 403-408, 2006

    46 Oudry J, "Cross-validation of magnetic resonance elastography and ultrasound-based transient elastography: a preliminary phantom study" 30 : 1145-1150, 2009

    47 Motosugi U, "Cross-validation of MR elastography and ultrasound transient elastography in liver stiffness measurement: discrepancy in the results of cirrhotic liver" 35 : 607-610, 2012

    48 Bland JM, "Comparing methods of measurement: why plotting difference against standard method is misleading" 346 : 1085-1087, 1995

    49 Yin M, "Assessment of hepatic fibrosis with magnetic resonance elastography" 5 : 1207-1213, 2007

    50 Bedossa P, "An algorithm for the grading of activity in chronic hepatitis C" The METAVIR Cooperative Study Group 24 : 289-293, 1996

    51 Bland JM, "Agreed statistics: measurement method comparison" 116 : 182-185, 2012

    52 Taouli B, "Advanced MRI methods for assessment of chronic liver disease" 193 : 14-27, 2009

    53 Rustogi R, "Accuracy of MR elastography and anatomic MR imaging features in the diagnosis of severe hepatic fibrosis and cirrhosis" 35 : 1356-1364, 2012

    54 Stebbing J, "A meta-analysis of transient elastography for the detection of hepatic fibrosis" 44 : 214-219, 2010

    55 De Groote J, "A classification of chronic hepatitis" 2 : 626-628, 1968

    56 McGill DB, "A 21-year experience with major hemorrhage after percutaneous liver biopsy" 99 : 1396-1400, 1990

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2023 평가 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
    2020-01-01 등재 등재학술지 유지 (해외등재 학술지 평가) KCI등재
    2016-11-15 학회명변경 영문명 : The Korean Radiological Society -> The Korean Society of Radiology KCI등재
    2010-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2007-01-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2006-01-01 등재 등재후보 1차 PASS (등재후보1차) KCI등재후보
    2003-01-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 1.61 0.46 1.15
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.93 0.84 0.494 0.06
    더보기
    해외이동버튼