      The ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 128 channel computerized data analysis system using microcomputer for basic research of electrophysiology and electrical propagation. The bipolar electrogram information is acquired from 128 cardiac sites simultaneously at a sampling rate of 1 ksampls/sec with continuous and total data storage of up to 30 seconds. When the reference electrogram is selected and reference point is picked up, delay time from the reference point is displayed on three dimensional diagram of the heart. System design permits easy expansion to almost 256 simul-taneous sites. this system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the result of diagnosis and surgical treatment for cardiac arrhythmia
      번역하기

      The ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 128 channel computerized data analysis system using microcomputer for basic researc...

      The ability to map and ablate the sometimes fleeting automatic atrial tachycardia is greatly enhanced by computerized mapping systems. In this study, we have developed 128 channel computerized data analysis system using microcomputer for basic research of electrophysiology and electrical propagation. The bipolar electrogram information is acquired from 128 cardiac sites simultaneously at a sampling rate of 1 ksampls/sec with continuous and total data storage of up to 30 seconds. When the reference electrogram is selected and reference point is picked up, delay time from the reference point is displayed on three dimensional diagram of the heart. System design permits easy expansion to almost 256 simul-taneous sites. this system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the result of diagnosis and surgical treatment for cardiac arrhythmia

      더보기

      목차 (Table of Contents)

      • Ⅰ. 서론
      • Ⅱ. 시스템 구성
      • Ⅲ. 제안된 소프트웨어
      • 1. 데이터 획득부 설계
      • 2. 가상 심장 모형의 제작
      • Ⅰ. 서론
      • Ⅱ. 시스템 구성
      • Ⅲ. 제안된 소프트웨어
      • 1. 데이터 획득부 설계
      • 2. 가상 심장 모형의 제작
      • 3. 테이터 표현
      • Ⅳ. 결론
      • 참고문헌
      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼