      The biggest obstacle to the commercialization of small and medium size microgrid (MG) is the reliability and economics of MG operation and maintenance. In this paper, we propose an autonomous operation method that is implemented as an application prog...

      The biggest obstacle to the commercialization of small and medium size microgrid (MG) is the reliability and economics of MG operation and maintenance. In this paper, we propose an autonomous operation method that is implemented as an application program installed in the MG operating system in emergency situations. The proposed algorithm consists of four steps of distinction, recognition, determination and control of emergency situations that can occur in MG. A fuzzy-based situation decision algorithm has been proposed to eliminate the barriers of autonomous operation in actual emergency situation such as occurrence of bad data and communication delay. In addition, countermeasures have been suggested for cases where multiple emergency situations have occurred in combination. The proposed algorithm was tested in a 500㎾ actual microgrid site of a university. Through the test, the validity of the proposed method and its applicability to practical MG operation are verified.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 제안한 MG 비상상황의 자율운전 알고리즘
      • 3. 사례연구
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 제안한 MG 비상상황의 자율운전 알고리즘
      • 3. 사례연구
      • 4. 결론
      • References
      더보기

      참고문헌 (Reference)

      1 W. El-khattam, "Resolving the impact of distributed renewable generation on directional overcurrent relay coordination : a case study" 3 (3): 415-425, 2009

      2 T. Kato, "Priority-based hierarchical operational management for multiagent-based microgrids" 7 (7): 2051-2078, 2014

      3 "Microgrid multi-client study"

      4 O. V. G. Swathika, "Fuzzy decision and graph algorithms aided adaptive protection of microgrid" 117 : 1078-1084, 2017

      5 T. S. Ustun, "Fault current coefficient and time delay assignment for microgrid protection system with central protection unit" 28 (28): 598-606, 2013

      6 F. Coffele, "An adaptive overcurrent protection scheme for distribution networks" 30 (30): 561-568, 2015

      7 B. J. Brearley, "A review on issues and approaches for microgrid protection" 67 : 988-997, 2017

      8 C. Li, "A review of islanding detection methods for microgrid" 35 : 211-220, 2014

      9 Z. Liu, "A multiagent system-based protection and control scheme for distribution system with distributed-generation integration" 32 (32): 536-545, 2017

      10 D. Q. Oliverira, "A fuzzy-based approach for microgrids islanded operation" 178-189, 2017

      1 W. El-khattam, "Resolving the impact of distributed renewable generation on directional overcurrent relay coordination : a case study" 3 (3): 415-425, 2009

      2 T. Kato, "Priority-based hierarchical operational management for multiagent-based microgrids" 7 (7): 2051-2078, 2014

      3 "Microgrid multi-client study"

      4 O. V. G. Swathika, "Fuzzy decision and graph algorithms aided adaptive protection of microgrid" 117 : 1078-1084, 2017

      5 T. S. Ustun, "Fault current coefficient and time delay assignment for microgrid protection system with central protection unit" 28 (28): 598-606, 2013

      6 F. Coffele, "An adaptive overcurrent protection scheme for distribution networks" 30 (30): 561-568, 2015

      7 B. J. Brearley, "A review on issues and approaches for microgrid protection" 67 : 988-997, 2017

      8 C. Li, "A review of islanding detection methods for microgrid" 35 : 211-220, 2014

      9 Z. Liu, "A multiagent system-based protection and control scheme for distribution system with distributed-generation integration" 32 (32): 536-545, 2017

      10 D. Q. Oliverira, "A fuzzy-based approach for microgrids islanded operation" 178-189, 2017

      11 G. Kyriakarakos, "A fuzzy logic energy management system for polygeneration microgrids" 41 : 315-327, 2012

      12 M. A. Zamani, "A communication-assisted protection strategy for inverterbased medium-voltage microgrids" 3 (3): 2088-2099, 2012

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 학술지 통합 (기타) KCI등재
      2001-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.27 0.27 0.24
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.21 0.19 0.366 0.08
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼