<P>A revised specification of ITER TF conductor was proposed as 'Option2' for the baseline design. The cabling pitches of early stages and the void fraction were adjusted in the consequence of previous R&D programs to improve the degradation...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107622076
2010
-
SCOPUS,SCIE
학술저널
495-498(4쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>A revised specification of ITER TF conductor was proposed as 'Option2' for the baseline design. The cabling pitches of early stages and the void fraction were adjusted in the consequence of previous R&D programs to improve the degradation...
<P>A revised specification of ITER TF conductor was proposed as 'Option2' for the baseline design. The cabling pitches of early stages and the void fraction were adjusted in the consequence of previous R&D programs to improve the degradation of performance against cyclic current loadings in the magnetic field. To obtain the characteristics of the developed design, which are related to the effect of the electromagnetic load, the mechanical parameters and the contact resistances between components of cable were investigated employing a specially developed device of cryogenic press in the transverse direction for a short sample of the conductor cable. Through the measurements, the mechanical characteristics against the cyclic loads were discussed, as well as the effect on inter-strand resistances, according to the cable design.</P>