RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      The effect of titanium nitride coating on the fatigue fracture resistance of rotary nickel titanium instruments

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      목차 (Table of Contents)

      • ABSTRACT
      • INTRODUCTION
      • MATERIALS AND METHODS
      • RESULTS
      • DISCUSSION
      • ABSTRACT
      • INTRODUCTION
      • MATERIALS AND METHODS
      • RESULTS
      • DISCUSSION
      • CONCLUSION
      • REFERENCES
      더보기

      참고문헌 (Reference)

      1 Matthews A, "Titanium nitride PVD coating technology" 1 (1): 93-104, 1985

      2 Zelada G, "The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments" 28 (28): 540-542, 2002

      3 PalDey S, "Single layer and multilayer wear resistant coatings of (Ti,Al)N: a review" 342 (342): 58-79, 2003

      4 Alapati SB, "Scanning electron microscope observations of new and used nickel-titanium rotary files" 29 (29): 667-669, 2003

      5 Parashos P, "Rotary NiTi instrument fracture and its consequences" 32 (32): 1031-1043, 2006

      6 Boxman R, "Principles and applications of vacuum arc coatings" 17 (17): 705-712, 1989

      7 Quinto DT, "High Temperature microhardness of hard coatings produced by physical and chemical vapor deposition" 153 (153): 19-36, 1987

      8 Peng Z, "Hard and wear-resistant titanium nitride coatings for cemented carbide cutting tools by pulsed high energy density plasma" 51 (51): 3085-3094, 2003

      9 Anderson ME, "Fracture resistance of electropolished rotary nickel-titanium endodontic instruments" 33 (33): 1212-1216, 2007

      10 Parashos P, "Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use" 30 (30): 722-725, 2004

      1 Matthews A, "Titanium nitride PVD coating technology" 1 (1): 93-104, 1985

      2 Zelada G, "The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments" 28 (28): 540-542, 2002

      3 PalDey S, "Single layer and multilayer wear resistant coatings of (Ti,Al)N: a review" 342 (342): 58-79, 2003

      4 Alapati SB, "Scanning electron microscope observations of new and used nickel-titanium rotary files" 29 (29): 667-669, 2003

      5 Parashos P, "Rotary NiTi instrument fracture and its consequences" 32 (32): 1031-1043, 2006

      6 Boxman R, "Principles and applications of vacuum arc coatings" 17 (17): 705-712, 1989

      7 Quinto DT, "High Temperature microhardness of hard coatings produced by physical and chemical vapor deposition" 153 (153): 19-36, 1987

      8 Peng Z, "Hard and wear-resistant titanium nitride coatings for cemented carbide cutting tools by pulsed high energy density plasma" 51 (51): 3085-3094, 2003

      9 Anderson ME, "Fracture resistance of electropolished rotary nickel-titanium endodontic instruments" 33 (33): 1212-1216, 2007

      10 Parashos P, "Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use" 30 (30): 722-725, 2004

      11 Madarati AA, "Factors contributing to the separation of endodontic files" 204 (204): 241-245, 2008

      12 Tripi TR, "Fabrication of hard coatings on NiTi instruments" 29 (29): 132-134, 2003

      13 Schafer E, "Effect of physical vapor deposition on cutting efficiency of nickel-titanium files" 28 (28): 800-802, 2002

      14 Haikel Y, "Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments" 25 (25): 434-440, 1999

      15 Sattapan B, "Defects in rotary nickel-titanium files after clinical use" 26 (26): 161-165, 2000

      16 Yao JH, "Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model" 32 (32): 55-57, 2006

      17 Li UM, "Cyclic fatigue of endodontic nickel titanium rotary instruments : static and dynamic tests" 28 (28): 448-451, 2002

      18 Tripi TR, "Cyclic fatigue of different nickel-titanium endodontic rotary instruments" 102 (102): e106-e114, 2006

      19 Gambarini G, "Cyclic fatigue of ProFile rotary instruments after prolonged clinical use" 34 (34): 386-389, 2001

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2014-11-11 학회명변경 한글명 : 대한치과기재학회 -> 대한치과재료학회
      영문명 : The Korea Research Society For Dental Materials -> Korean Society For Dental Materials
      KCI등재
      2014-11-11 학술지명변경 한글명 : 대한치과기재학회지 -> 대한치과재료학회지
      외국어명 : J. Korea Res. Soc. Dent. Mater. -> Korean Journal of Dental Materials
      KCI등재
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.33 0.33 0.25
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.2 0.18 0.408 0.07
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼