RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재

    Diagnostic Assay of Phenol Ions in Human Tissue

    한글로보기

    https://www.riss.kr/link?id=A104429943

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    A voltammetric assay of phenol ions was investigated using three electrode systems of graphite pencil working, reference and counter electrodes. Under optimum analytical parameters, square wave stripping working ranges were attained at a mili range of 10~80 mg/L and a micro range of 20~90 ug/L using seawater electrolyte. The developed sensor was applied to tap water and the human body system of a smoker. It was found that the methods can be applied to in vivo fluid or medicinal diagnosis.
    번역하기

    A voltammetric assay of phenol ions was investigated using three electrode systems of graphite pencil working, reference and counter electrodes. Under optimum analytical parameters, square wave stripping working ranges were attained at a mili range of...

    A voltammetric assay of phenol ions was investigated using three electrode systems of graphite pencil working, reference and counter electrodes. Under optimum analytical parameters, square wave stripping working ranges were attained at a mili range of 10~80 mg/L and a micro range of 20~90 ug/L using seawater electrolyte. The developed sensor was applied to tap water and the human body system of a smoker. It was found that the methods can be applied to in vivo fluid or medicinal diagnosis.

    더보기

    참고문헌 (Reference)

    1 S. Hu, "Voltammetric determination of 4- nitrophenol at a sodium montmorilloniteanthraquinone chemically modified glassy carbon electrode" 54 : 115-123, 2001

    2 R. M. de Carvalho, "Simultaneous determination of phenol isomers in binary mixtures by differential pulse voltammetry using carbon fibre electrode and neural network with pruning as a multivariate calibration tool" 420 : 109-121, 2000

    3 Z. Q. Zhang, "Simultaneous cathodic stripping voltammetric determination of mercury, cobalt, nickel and palladium by mixed binder carbon paste electrode containing dimethylglyoxime" 333 : 119-124, 1996

    4 X. Liu, "Oxidized multiwalled carbon nanotubes as a novel solid-phase micro extraction fiber for determination of phenols in aqueous samples" 1165 : 10-17, 2007

    5 M. A. Ghanem, "Microwave activation of electrochemical processes: High temperature phenol and triclosan electro-oxidation at carbon and diamond electrodes" 53 : 1092-1099, 2007

    6 S. C. Moldoveanu, "Gas chromatography/mass spectrometry versus liquid chromatography/fluorescence detection in the analysis of phenols in mainstream cigarette smoke" 1141 : 90-97, 2007

    7 N. G. Simoes, "Experimental and statistical validation of SPME-GC–S analysis of phenol and chlorophenols in raw and treated water" 68 : 501-510, 2007

    8 J. Iniesta, "Electrochemical oxidation of phenol at boron-doped diamond electrode" 46 : 3573-3578, 2001

    9 H. Wang, "Electrochemical degradation of 4-chlorophenol using a novel Pd/C gas-diffusion electrode" 77 : 58-, 2007

    10 M. Pakuła, "Electrochemical and FTIR studies of the mutual influence of lead(II) or iron(III) and phenol on their adsorption from aqueous acid solution by modified activated carbons" 69 : 209-219, 2007

    1 S. Hu, "Voltammetric determination of 4- nitrophenol at a sodium montmorilloniteanthraquinone chemically modified glassy carbon electrode" 54 : 115-123, 2001

    2 R. M. de Carvalho, "Simultaneous determination of phenol isomers in binary mixtures by differential pulse voltammetry using carbon fibre electrode and neural network with pruning as a multivariate calibration tool" 420 : 109-121, 2000

    3 Z. Q. Zhang, "Simultaneous cathodic stripping voltammetric determination of mercury, cobalt, nickel and palladium by mixed binder carbon paste electrode containing dimethylglyoxime" 333 : 119-124, 1996

    4 X. Liu, "Oxidized multiwalled carbon nanotubes as a novel solid-phase micro extraction fiber for determination of phenols in aqueous samples" 1165 : 10-17, 2007

    5 M. A. Ghanem, "Microwave activation of electrochemical processes: High temperature phenol and triclosan electro-oxidation at carbon and diamond electrodes" 53 : 1092-1099, 2007

    6 S. C. Moldoveanu, "Gas chromatography/mass spectrometry versus liquid chromatography/fluorescence detection in the analysis of phenols in mainstream cigarette smoke" 1141 : 90-97, 2007

    7 N. G. Simoes, "Experimental and statistical validation of SPME-GC–S analysis of phenol and chlorophenols in raw and treated water" 68 : 501-510, 2007

    8 J. Iniesta, "Electrochemical oxidation of phenol at boron-doped diamond electrode" 46 : 3573-3578, 2001

    9 H. Wang, "Electrochemical degradation of 4-chlorophenol using a novel Pd/C gas-diffusion electrode" 77 : 58-, 2007

    10 M. Pakuła, "Electrochemical and FTIR studies of the mutual influence of lead(II) or iron(III) and phenol on their adsorption from aqueous acid solution by modified activated carbons" 69 : 209-219, 2007

    11 R.H. Carvalho, "Electro-oxidation of phenol on zeolite/graphite composite electrodes Part 2. Influence of zeolite type and composition" 253 : 170-175, 2006

    12 Y.J. Feng, "Electro-catalytic oxidation of phenol on several metaloxide electrodes in aqueous solution" 37 : 2399-2407, 2003

    13 G. Marrubini, "Direct Analysis of Phenol, Catechol and Hydroquinone in Human Urine by Coupled-Column HPLC with Fluorimetric Detection" 62 : 25-31, 2005

    14 E. Baltussen, "Automated Sorptive Extraction-Thermal Desorption-Gas Chromatography-Mass Spectrometry Analysis: Determination of Phenols in Water Samples" 116 : 471-474, 1999

    15 V. Andrei, "Application of water-soluble polymers as modifiers in electrophoretic analysis of phenols" 24 : 2099-2105, 2003

    16 M. Saeed, "Application of Capillary Electrochromatography (CEC) for the Analysis of Phenols in Mainstream and Sidestream Tobacco Smoke" 49 (49): 391-398, 1999

    17 D. A. Palnero, "Analysis of Phenol in an Over-the-Counter Sore Throat Spray by Cyclic Voltammetry" 90 (90): 165-171, 2001

    18 H. Yi, "Adsorption stripping voltammetry of phenol at Nafion-modified glassy carbon electrode in the presence of surfactants" 55 : 1205-1210, 2001

    19 Silvana Andreescu, "A new electrocatalytic mechanism for the oxidation of phenols at platinum electrodes" 5 : 681-688, 2003

    20 T. N. Ermolaeva, "A Sensitive Piezoelectric Crystal Sensor for Analyzing Phenols in Air" 74 (74): 1993204-, 2001

    더보기

    동일학술지(권/호) 다른 논문

    동일학술지 더보기

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2022 평가 계속평가 신청대상 (계속평가)
    2021-12-01 등재 등재후보로 하락 (재인증) KCI등재후보
    2019-01-29 학회명변경 한글명 : 한국유화학회 -> 한국응용과학기술학회
    영문명 : The Korean Oil Chemists' Society -> The Korean Society of Applied Science and Technology (KSAST)
    KCI등재
    2019-01-01 학술지명변경 한글명 : 오일 및 응용과학 학회지 -> 한국응용과학기술학회지
    외국어명 : Journal of Oil & Applied Science -> Journal of the Korean Applied Science and Technology
    KCI등재
    2019-01-01 학술지명변경 한글명 : 오일 및 응용과학 학회지 -> 한국응용과학기술학회지
    외국어명 : Journal of Oil & Applied Science -> Journal of the Korean Applied Science and Technology
    KCI등재
    2018-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2017-06-01 학술지명변경 한글명 : 韓國油化學會誌 -> 오일 및 응용과학 학회지
    외국어명 : Journal of The Korean Oil Chemists' Society -> Journal of Oil & Applied Science
    KCI등재
    2015-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2011-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2009-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2006-01-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2005-01-01 등재 등재후보 1차 PASS (등재후보1차) KCI등재후보
    2004-01-01 등재 등재후보학술지 유지 (등재후보1차) KCI등재후보
    2002-07-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 0.3 0.3 0.3
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.27 0.24 0.354 0.08
    더보기

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼