Aqueous arsenic(Ⅲ), arsenic(Ⅴ) and dimethyl arsinic acid(DMAA) were separated by ion exchange chromatograph with a 60cm long and 0.8cm wide columm. The elution was proceeded with 20㎖ of 0.006M trichloro acetic acid(TCA), 30㎖ of 0.2M TCA, follo...

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A19598994
1986
Korean
430.000
학술저널
245-254(10쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
Aqueous arsenic(Ⅲ), arsenic(Ⅴ) and dimethyl arsinic acid(DMAA) were separated by ion exchange chromatograph with a 60cm long and 0.8cm wide columm. The elution was proceeded with 20㎖ of 0.006M trichloro acetic acid(TCA), 30㎖ of 0.2M TCA, follo...
Aqueous arsenic(Ⅲ), arsenic(Ⅴ) and dimethyl arsinic acid(DMAA) were separated by ion exchange chromatograph with a 60cm long and 0.8cm wide columm. The elution was proceeded with 20㎖ of 0.006M trichloro acetic acid(TCA), 30㎖ of 0.2M TCA, followed by 40㎖ of 1.5M NH_4OH, and collected effluents were analyzed by atomic absorption spectrometry with an electrothermal atomizer. Arsenic(Ⅲ) was eluted first, and then Arsenic(Ⅴ) and finally DMAA was eluted with a satisfactory separation. A column filled with 8% crosslinked anion and cation exchange resins showed the best separation results.
On the Relation Between Function Algebra and the Banach Algebra of Operators
Aedes aegypti와 Culex pipiens pallens 모기의 난황 단백질 합성에 관한 연구