So called "Saemaul-Boiler"is a domestic heating system composing a closed loop of tube, through which is circulating a hot water mobilized by natural convection effect in boiler. This heating system was simplified to a single phase closed th...

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A19596434
1992
Korean
505
학술저널
153-161(9쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
So called "Saemaul-Boiler"is a domestic heating system composing a closed loop of tube, through which is circulating a hot water mobilized by natural convection effect in boiler. This heating system was simplified to a single phase closed th...
So called "Saemaul-Boiler"is a domestic heating system composing a closed loop of tube, through which is circulating a hot water mobilized by natural convection effect in boiler. This heating system was simplified to a single phase closed thermo-loop, having an element of helically coiled tube heated externally by electric resistance wire.
The investigation was put on some parameters of coil tube such as helix angle, curvature ratio and tube diameter in order to understand their effects on mass flow rate of working fluid in the loop system.
From the results of the experiment it was shown that :
1) The heilx angle and diameter of coil tube might have a considerable importance on improuvement of thermal load by increasing mass flux of working fluid.
2) But the curvature ratio had relatively negligible effect.