RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      라텍스 장갑과 마이크로 파이버 속장갑 착용 시 손의 피부수분도 분포 = Distribution of Skin Hydration on the Hand while Wearing Latex Gloves and Inner Gloves

      한글로보기

      https://www.riss.kr/link?id=A103758211

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study investigated the effects of wearing latex gloves with inner gloves on the skin hydration of the hands. Fifteen young males participated in the following three conditions: bare hand (BH), latex glove (LG), and latex glove with inner glove co...

      This study investigated the effects of wearing latex gloves with inner gloves on the skin hydration of the hands. Fifteen young males participated in the following three conditions: bare hand (BH), latex glove (LG), and latex glove with inner glove condition (LGIG) at an air temperature of $28^{\circ}C$ with 50%RH. Subjects typed a book for 120 min. The results were as follows. Skin hydration was greater for LG and LGIG than BH (p<.001), but no difference was found between LG and LGIG. Skin hydration showed greater values on the thenar and dorsum compared to the palm for both LG and LGIG (p<.05). Skin hydration on the thenar increased during the typing for LG and LGIG, but on the dorsum, palm and finger maintained after 40 min typing. There were positive relationships between hand skin hydration and hand temperature (p<.05). Subjects indicated 'much warmer' and 'more humid' for the LG and LGIG compared to the BH (p<.001), but no differences were found between LG and LGIG. In conclusion, wearing inner gloves inside latex gloves did not induce a reduction of skin hydration and hand temperature; however, significant differences were found in all measurements between bare hands and gloved hands.

      더보기

      참고문헌 (Reference)

      1 Candas, V., "Thermal comfort: Multisensory interactions?" 24 (24): 33-36, 2005

      2 Krylov, O. A., "The sweating reactions of the palm" 43 (43): 152-155, 1957

      3 Min, P. K., "The changes of transepidermal water loss and the recovery rate of the epidermal permeability barrier according to the skin surface temperature and temperature in a diffusion chamber" 34 (34): 875-885, 1996

      4 Baker, H., "Textbook of dermatology Volume 2" Blackwell Scientific Publications 249-255, 1972

      5 Koh, J. S., "Skin charcteristics of normal Korean subjects according to sex and site using non-invasive bioengineering methods" 36 (36): 855-864, 1998

      6 Bucks, D., "Percutaneous absorption: Drug-cosmetics-mechanisms-methodology (3rd ed.)" Marcel Dekker, Inc 81-105, 1999

      7 Hongbo Zhai, "Occlusion vs. skin barrier function" Wiley 8 (8): 1-6, 2002

      8 R. Wells, "Laboratory assessment of the effect of heavy rubber glove thickness and sizing on effort, performance and comfort" Elsevier BV 40 (40): 386-391, 2010

      9 Johan du Plessis, "International guidelines for the in vivo assessment of skin properties in non-clinical settings: Part 2. transepidermal water loss and skin hydration" Wiley 19 (19): 265-278, 2013

      10 Cao, W., "Improving comfort in clothing (1st ed.)" Woodhead Publishing Limited 370-384, 2011

      1 Candas, V., "Thermal comfort: Multisensory interactions?" 24 (24): 33-36, 2005

      2 Krylov, O. A., "The sweating reactions of the palm" 43 (43): 152-155, 1957

      3 Min, P. K., "The changes of transepidermal water loss and the recovery rate of the epidermal permeability barrier according to the skin surface temperature and temperature in a diffusion chamber" 34 (34): 875-885, 1996

      4 Baker, H., "Textbook of dermatology Volume 2" Blackwell Scientific Publications 249-255, 1972

      5 Koh, J. S., "Skin charcteristics of normal Korean subjects according to sex and site using non-invasive bioengineering methods" 36 (36): 855-864, 1998

      6 Bucks, D., "Percutaneous absorption: Drug-cosmetics-mechanisms-methodology (3rd ed.)" Marcel Dekker, Inc 81-105, 1999

      7 Hongbo Zhai, "Occlusion vs. skin barrier function" Wiley 8 (8): 1-6, 2002

      8 R. Wells, "Laboratory assessment of the effect of heavy rubber glove thickness and sizing on effort, performance and comfort" Elsevier BV 40 (40): 386-391, 2010

      9 Johan du Plessis, "International guidelines for the in vivo assessment of skin properties in non-clinical settings: Part 2. transepidermal water loss and skin hydration" Wiley 19 (19): 265-278, 2013

      10 Cao, W., "Improving comfort in clothing (1st ed.)" Woodhead Publishing Limited 370-384, 2011

      11 Kuno, Y., "Human perspiration" Thomas 1956

      12 Kligman, A. M., "Handbook of occupational dermatology" Springer-Verlag Berlin Heidelberg 76-80, 2000

      13 Dorte W. Ramsing, "Effect of glove occlusion on human skin (II)" Wiley 34 (34): 258-262, 1996

      14 Dorte W. Ramsing, "Effect of glove occlusion on human skin (I)" Wiley 34 (34): 1-5, 1996

      15 E. Berardesca, "EEMCO guidance for the assessment of stratum corneum hydration: electrical methods" Wiley 3 (3): 126-132, 1997

      16 Hwang, K., "Distribution of hairs and sweat glands in body regions of Korean adults: A morphometrical study" Seoul National University 1992

      17 Deirdre Cronin Vorih, "Comparison of Nitrile Gloves and Nitrile over Nomex Gloves" Elsevier BV 28 (28): 288-302, 2009

      18 Lee, S. H., "Comparative measurement of skin surface hydration using a hydrometer and corneometer" 32 (32): 599-603, 1994

      19 A.D. Roberts, "Comfort and frictional properties of dental gloves" Elsevier BV 24 (24): 339-343, 1996

      20 Choi, B. M., "Clinical study of allergic reaction to latex gloves in hospital personnel" 4 (4): 30-37, 1994

      21 Park, S. J., "Change of evaporation rate on local skin by posture for designing comfortable clothing" 32 (32): 245-253, 1994

      22 A. Kopka, "Anaesthetists should wear gloves - touch sensitivity is improved with a new type of thin glove" Wiley 49 (49): 459-462, 2005

      23 Sanja Kezic, "Absorption of chemicals through compromised skin" Springer Nature 82 (82): 677-688, 2009

      24 Lee, J. Y., "A study on the body surface area of Korea adults" Seoul National University 2005

      25 Jang, H. Y., "A study of transepidermal water loss at various anatomical sites of the skin" 34 (34): 402-406, 1996

      26 Korean Agency for Technology and Standards, "6차 인체치수조사" Size Korea

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1998-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      1977-05-30 학술지명변경 외국어명 : 미등록 -> Journal of the Korean Society of Clothing and Textiles
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.64 0.64 0.67
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.69 0.7 0.844 0.14
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼