      Validity and reliability of POM-Checker in measuring shoulder range of motion : Protocol for a single center comparative study

      한글로보기

      https://www.riss.kr/link?id=A107451430

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P><P><B>Introduction:</B></P><P>Assessments of the range of motion (ROM) in human joints have been widely used to evaluate the joint condition. Although maker based motion captu...

      <P><B>Abstract</B></P><P><B>Introduction:</B></P><P>Assessments of the range of motion (ROM) in human joints have been widely used to evaluate the joint condition. Although maker based motion capture system is the most popular and practical method in the clinical field, there have been limitations such as the relatively long time required in procedure or influence of attached markers on natural movement. Recently, markerless motion capture systems have been actively developed due to their relatively lower cost and convenience for installation. The POM-Checker (Team Elysium Inc., Seoul, Rep of Korea), a markerless motion capture system, was developed with new algorithms to assess the ROM in human joints. However, the measure of the POM-Checker has not been compared with a golden-standard device in evaluating the ROM in the human joints. So we developed a protocol to evaluate the validation and reliability of the POM-Checker in measuring the shoulder ROM. This study will also provide a standard procedure to measure the shoulder ROM with the POM-Checker and 3D motion analysis system simultaneously.</P><P><B>Methods/design:</B></P><P>This protocol is for a single institution comparative study to evaluate the validity and reliability of POM-Checker. Six participants will be recruited. We will measure the angles of shoulder abduction and flexion with POM-Checker and 3D motion analysis system simultaneously. The primary outcome is the angles of shoulder abduction and flexion.</P><P><B>Discussion:</B></P><P>This will be the first study to analyze the validity and reliability of POM-Checker in measuring shoulder ROM. Although the sample size of this study is small, it may not influence on the results conclusively, because the measures are very precise numerical angles. Furthermore, the angles of shoulder movements will be measured with both devices simultaneously.</P><P><B>Conclusion:</B></P><P>The results of the study will be helpful to find out the validity and reliability of a new developed ROM measure device, POM-Checker, by comparison with a golden standard system, 3D motion capture system, in measuring the shoulder ROM. It will also contribute to use of the POM-Checker in measuring the ROMs in many human joints</P>

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼