    Quantification of volumetric absorption for absorbable implant using micro-CT

    한글로보기

    https://www.riss.kr/link?id=T12947974

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Introduction: The purpose of the study was to quantify the VA (volumetric absorption) from the result of osseointegration in micro-CT analysis. We have developed a new method to evaluate the osseointegration and absorption of the absorbable implant using micro-CT images. The measurement was correlated with the histomorphometric analysis.

    Methods: For the procedure, mandibular 2 and 4 premolars were extracted bilaterally from seven experimental dogs (beagle dog), and installed two PLA-TCP 30% implants on each side.
    For close examination, the implants with its surrounding tissue were dissected to safely remove implants from the figures in sequence of 4 week, 8 week, and 12 weeks lapse since the installation. Seven implants were damaged and excluded and total 21 implants samples were used for the analysis.
    From the Micro- CT scan images, the confidence connected segmentation, connected threshold segmentation, morphology operation and labeling algorithm were applied, and volumetric analysis was performed between bone and implant to measure the VBIC (Volumetric Bone-Implant contact) and VA(Volumetric Absorption). The implant slices were prepared by dissecting the center area of the sample tissues in axial direction for histomorphometric analysis of BIC (Bone-Implant contact) and BA (Bone Area).

    Results: As a result, the mean of VA and VBIC increased significantly with an increase in the healing period (p<.01 ANOVA, p<0.05 the turkey's multiple comparison test)
    The BA and the BIC did increase over the implant installation time period, but the difference of mean did not show significant difference. After analyzing the correlation between the VBIC and the VA based on Micro-CT analysis (which showed significant difference previously), it showed significant difference in correlation 0.463.

    Conclusions: A compare of two different methods for quantify of osseointegration, histomorphometric analysis was limited to the absorbable implant analysis because the absorbable implant change in the size. In contrast, VA of absorbable implant showed significant correlation with VBIC, and it has provided a new parameter for osseointegration evaluation. Therefore, quantification of VA is required to evaluate osseointegrationun of an absorbable implant besides the other existing methods.
    번역하기

    Introduction: The purpose of the study was to quantify the VA (volumetric absorption) from the result of osseointegration in micro-CT analysis. We have developed a new method to evaluate the osseointegration and absorption of the absorbable implant u...

    Introduction: The purpose of the study was to quantify the VA (volumetric absorption) from the result of osseointegration in micro-CT analysis. We have developed a new method to evaluate the osseointegration and absorption of the absorbable implant using micro-CT images. The measurement was correlated with the histomorphometric analysis.

    Methods: For the procedure, mandibular 2 and 4 premolars were extracted bilaterally from seven experimental dogs (beagle dog), and installed two PLA-TCP 30% implants on each side.
    For close examination, the implants with its surrounding tissue were dissected to safely remove implants from the figures in sequence of 4 week, 8 week, and 12 weeks lapse since the installation. Seven implants were damaged and excluded and total 21 implants samples were used for the analysis.
    From the Micro- CT scan images, the confidence connected segmentation, connected threshold segmentation, morphology operation and labeling algorithm were applied, and volumetric analysis was performed between bone and implant to measure the VBIC (Volumetric Bone-Implant contact) and VA(Volumetric Absorption). The implant slices were prepared by dissecting the center area of the sample tissues in axial direction for histomorphometric analysis of BIC (Bone-Implant contact) and BA (Bone Area).

    Results: As a result, the mean of VA and VBIC increased significantly with an increase in the healing period (p<.01 ANOVA, p<0.05 the turkey's multiple comparison test)
    The BA and the BIC did increase over the implant installation time period, but the difference of mean did not show significant difference. After analyzing the correlation between the VBIC and the VA based on Micro-CT analysis (which showed significant difference previously), it showed significant difference in correlation 0.463.

    Conclusions: A compare of two different methods for quantify of osseointegration, histomorphometric analysis was limited to the absorbable implant analysis because the absorbable implant change in the size. In contrast, VA of absorbable implant showed significant correlation with VBIC, and it has provided a new parameter for osseointegration evaluation. Therefore, quantification of VA is required to evaluate osseointegrationun of an absorbable implant besides the other existing methods.

    더보기

    목차 (Table of Contents)

    • CONTENTS
    • Abstract 1
    • Contents 4
    • Introduction 6
    • Material and Methods 9
    • CONTENTS
    • Abstract 1
    • Contents 4
    • Introduction 6
    • Material and Methods 9
    • Results 20
    • Discussion 28
    • Reference 34
    • 국문초록 40
    • LIST OF TABLES
    • [Table 1] 12
    • [Table 2] 21
    • [Table 3] 23
    • [Table 4] 26
    • [Table 5] 27
    • LIST OF FIGURES
    • [Figure 1] 9
    • [Figure 2] 11
    • [Figure 3] 13
    • [Figure 4] 14
    • [Figure 5] 16
    • [Figure 6] 18
    • [Figure 7] 19
    • [Figure 8] 22
    • [Figure 9] 24
    • [Figure 10] 25
    • [Figure 11] 25
    • [Figure 12] 27
    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼