RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Agri-environmental System Engineering and Energy : Original Article ; Emissions of Odor, Ammonia, Hydrogen Sulfide, and Volatile Organic Compounds from Shallow-Pit Pig Nursery Rooms = Agri-environmental System Engineering and Energy : Original Article ; Emissions of Odor, Ammonia, Hydrogen Sulfide, and Volatile Organic Compounds from Shallow-Pit Pig Nursery Rooms

      한글로보기

      https://www.riss.kr/link?id=A100021105

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: The objective of this study was to measure emissions of gases (ammonia (NH3), hydrogen sulfide (H2S) and carbondioxide (CO2)), volatile organic compounds (VOC) and odor from two shallow pit pig nursery rooms. Gas and odor reductionpractices f...

      Purpose: The objective of this study was to measure emissions of gases (ammonia (NH3), hydrogen sulfide (H2S) and carbondioxide (CO2)), volatile organic compounds (VOC) and odor from two shallow pit pig nursery rooms. Gas and odor reductionpractices for swine operations based on the literature were also discussed. Methods: This study was conducted for 60 daysat a commercial swine nursery facility which consisted of four identical rooms with mechanical ventilations. Two rooms(room 1 (R1) and room 2 (R2)) with different pig numbers and ventilation rates were used in this study. The pig manurefrom both the R1 and R2 were characterized. Indoor/outdoor temperatures, ventilation rates/duration, NH3, H2S, CO2, andVOC concentrations of the ventilation air were measured periodically (3-5 times/week). Odor concentrations of theventilations were measured two times on two days. Three different types of gas and odor reduction practices (diet control,chemical method, and biological method) were discussed in this study. Results: The volatile solids to total solids ratio(VS/TS) and crude protein (CP) value of pig manure indicated the pig manure had high potential for gas and odor emissions. The NH3, H2S, CO2 and VOC concentrations were measured in the ranges of 1.0-13.3, 0.1-5.7, 1600-3000 and 0.0-1.83 ppm,respectively. The NH3 concentrations were found significantly higher than H2S concentrations for both rooms. The odorconcentrations were measured in the range of 2853-4432 OUE/m3. There was significant difference in odor concentrationsbetween the two rooms which was due to difference in pig numbers and ventilation duration. The literature studies showedthat simultaneous use of dietary control and biofiltration practices will be more effective and environmentally friendly forgas and odor reductions from pig barns. Conclusions: The gas and odor concentrations measured in the ventilation air fromthe pig rooms indicate an acute need for using gas and odor mitigation technologies. Adopting diet control and biofiltrationpractices simultaneously could be the best option for mitigating gas and odor emissions from pig barns.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼