RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      콘택트렌즈 착용시 사용하는 인공누액이 인체각막상피세포에 미치는 영향 = Effect of Artificial Tears Used in Contact Lens-wearing Eyes on Human Corneal Epithelial Cells in Vitro

      한글로보기

      https://www.riss.kr/link?id=A100523749

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To investigate the biologic effects of topical ocular artificial tears used in patients wearing contact lens on in vitro corneal epithelial cells. Methods: The efficacies of the topical artificial tears IrisⓇ, IrisplusⓇ, Eyemiru contact pureⓇ, and Eye2OⓇ were evaluated using the MTT and wound healing assays. Cell damage was determined using lactate dehydrogenase (LDH), and the solution ingredients were analyzed. Cellular morphologies were examined by inverted light microscopy and transmission electromicroscopy. Results: Metabolic activity of corneal epithelial cells, as determined by the MTT assay, decreased in the IrisⓇ eye drop group, but those of the other groups were similar to that of the control. The LDH titers increased up to one hour after IrisⓇ eye drop use, and the increased level was maintained for 24 hours. The other three artificial tears showed similar low LDH titers to that of the control. Cellular migration was not observed, although cellular damage to the corneal epithelial cells, such as chromatin margination and cytoplasmic organelle swelling, was prominent with IrisⓇ use. Conclusions: Among four brands of topical artificial tear drops used among patients wearing contact lens, IrisⓇ caused markedly more severe damage to cultured human corneal epithelial cells than did IrisplusⓇ, Eyemiru contact pureⓇ, or Eye2OⓇ. J Korean Ophthalmol Soc 2010;51(4):588-597
      번역하기

      Purpose: To investigate the biologic effects of topical ocular artificial tears used in patients wearing contact lens on in vitro corneal epithelial cells. Methods: The efficacies of the topical artificial tears IrisⓇ, IrisplusⓇ, Eyemiru c...

      Purpose: To investigate the biologic effects of topical ocular artificial tears used in patients wearing contact lens on in vitro corneal epithelial cells. Methods: The efficacies of the topical artificial tears IrisⓇ, IrisplusⓇ, Eyemiru contact pureⓇ, and Eye2OⓇ were evaluated using the MTT and wound healing assays. Cell damage was determined using lactate dehydrogenase (LDH), and the solution ingredients were analyzed. Cellular morphologies were examined by inverted light microscopy and transmission electromicroscopy. Results: Metabolic activity of corneal epithelial cells, as determined by the MTT assay, decreased in the IrisⓇ eye drop group, but those of the other groups were similar to that of the control. The LDH titers increased up to one hour after IrisⓇ eye drop use, and the increased level was maintained for 24 hours. The other three artificial tears showed similar low LDH titers to that of the control. Cellular migration was not observed, although cellular damage to the corneal epithelial cells, such as chromatin margination and cytoplasmic organelle swelling, was prominent with IrisⓇ use. Conclusions: Among four brands of topical artificial tear drops used among patients wearing contact lens, IrisⓇ caused markedly more severe damage to cultured human corneal epithelial cells than did IrisplusⓇ, Eyemiru contact pureⓇ, or Eye2OⓇ. J Korean Ophthalmol Soc 2010;51(4):588-597

      더보기

      참고문헌 (Reference)

      1 Foulks, GN, "What is dry eye and what does it mean to the contact lens wearer?" 29 : S96-100, 2003

      2 Businger U, "The etiology and management of three and nine o’clock staining" 16 : 136-139, 1989

      3 Lee JS, "The effects of artificial tear formulation and anti-inflammatory agents on the cultured keratocyted of rabbit" 39 : 42-51, 1998

      4 Freshney RI, "The culture environment: Substrate, gas phase, medium, and temparature, 2nd ed" Wiley-Liss 70-71, 1987

      5 Berdy GJ, "Preservative-free artificial tear preparations Assessment of corneal epithelial toxic effects" 110 : 528-532, 1992

      6 Burstein NL, "Preservative cytotoxic threshold for benzalkonium chloride and chlorhexidine digluconate in cat and rabbit corneas" 19 : 308-313, 1980

      7 Orsborn GN, "Practitioner survey: management of dry-eye symptoms in soft lens wearers" 4 : 23-26, 1989

      8 Reuben M, "Pilocarpine dispensation for the soft hydrophilic contact lens" 59 : 455-458, 1975

      9 Park YS, "Physiology of body fluid. In Physiology, 5th ed" Sin-Kwang publishing & printing 5-, 2000

      10 Green K, "Influence of various agents on corneal permeability" 72 : 897-905, 1971

      1 Foulks, GN, "What is dry eye and what does it mean to the contact lens wearer?" 29 : S96-100, 2003

      2 Businger U, "The etiology and management of three and nine o’clock staining" 16 : 136-139, 1989

      3 Lee JS, "The effects of artificial tear formulation and anti-inflammatory agents on the cultured keratocyted of rabbit" 39 : 42-51, 1998

      4 Freshney RI, "The culture environment: Substrate, gas phase, medium, and temparature, 2nd ed" Wiley-Liss 70-71, 1987

      5 Berdy GJ, "Preservative-free artificial tear preparations Assessment of corneal epithelial toxic effects" 110 : 528-532, 1992

      6 Burstein NL, "Preservative cytotoxic threshold for benzalkonium chloride and chlorhexidine digluconate in cat and rabbit corneas" 19 : 308-313, 1980

      7 Orsborn GN, "Practitioner survey: management of dry-eye symptoms in soft lens wearers" 4 : 23-26, 1989

      8 Reuben M, "Pilocarpine dispensation for the soft hydrophilic contact lens" 59 : 455-458, 1975

      9 Park YS, "Physiology of body fluid. In Physiology, 5th ed" Sin-Kwang publishing & printing 5-, 2000

      10 Green K, "Influence of various agents on corneal permeability" 72 : 897-905, 1971

      11 Wee WR, "Effect of artificial tears on cultured keratocytes in vitro" 14 : 273-279, 1995

      12 Jain MR, "Drug delivery though soft contact lenses" 72 : 150-154, 1988

      13 Dutot M, "Cytotoxicity of contact lens multipurpose solutions: Role of oxidative stress, mitochondrial activity and P2X7 cell death receptor activation" 33 : 138-145, 2008

      14 Lee JS, "Cytotoxicity of banzalkonium chlorid on the corneal epithelial cell of rabbit" 39 : 1326-1333, 1998

      15 Cha SH, "Corneal epithelial cellular dysfunction from banzalkonium chloride (BAC) in vitro" 32 : 180-184, 2004

      16 Korean Contact Lens Society, "Contact Lens: Principles and Practice, 2nd ed" Nae-Oi publishing & printing 187-193, 2007

      17 Solomon J, "Causes and treatments of peripheral corneal desiccation" 11 : 30-36, 1986

      18 Diebold Y, "Carbomer-versus cellulosebased artificial-tear formulations: morphologic and toxicologic effects on a corneal cell line" 17 : 433-440, 1998

      19 Kim K, "Acid-base balance. In Physiology" Eui-hak publishing & printing 20-, 1996

      20 Silbert JA, "A review of therapeutic agents and contact lens wear" 67 : 165-172, 1996

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.22 0.22 0.22
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.23 0.23 0.366 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼