      Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of 310℃ and 14.7 ㎫. Thus the MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In this work, the performance test of a prototype MCP was carried out under the same operating condition and hydro dynamic performance curves were obtained as a result. At the same time, installation effect of an M-Pitot type flowmeter was also investigated by CFD and experiment. Two flowmeters were installed at different locations and the measured values were compared to each other. The averaged deviation of the flowrate at the design point is about 5%.
      번역하기

      Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of 310℃ and 14.7 ㎫. Thus t...

      Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of 310℃ and 14.7 ㎫. Thus the MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In this work, the performance test of a prototype MCP was carried out under the same operating condition and hydro dynamic performance curves were obtained as a result. At the same time, installation effect of an M-Pitot type flowmeter was also investigated by CFD and experiment. Two flowmeters were installed at different locations and the measured values were compared to each other. The averaged deviation of the flowrate at the design point is about 5%.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 시험장치
      • 3. 시험결과
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 시험장치
      • 3. 시험결과
      • 4. 결론
      • 참고문헌
      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼