Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger"s evacua...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A76247881
2007
Korean
326
학술저널
26-31(6쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger"s evacua...
Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger"s evacuation path, it will reduce visibility and can cause fatalities by asphyxiation.
This study performs not only fire simulation with CFAST V6 but also evacuation simulation with EXODUS V4 for the purpose of taking measures for passengers"s life safety in subway fire. As a result of evacuation simulation without fire, evacuation times are 36 s for EXODUS V4 and simple hand calculation, and when fire is occurred fire, 101 persons evacuated in 32 s. Therefore, a countermeasure of evacuation in subway carriage fire is required to repression of fire and emergency exit.