RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      형상이 다른 접지전극에 접속된 심매설 봉상 접지전극의 임펄스접지임피던스 특성 = Impulse Ground Impedances of a Deeply Driven Ground Rod Combined with Different Shape Grounding Electrodes

      한글로보기

      https://www.riss.kr/link?id=A103688601

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This paper describes the characteristics of effective impulse ground impedance of deeply driven ground rods combined with grounding grid or counterpoises with needles. The potential rises of the test ground electrodes were measured as a function of the rise time of applied impulse currents and the effective impulse ground impedances were calculated The impulse ground impedances of deeply driven ground rods strongly depend on the rise time of impulse currents and significantly reduced by the connection of grounding grids in parallel.
      번역하기

      This paper describes the characteristics of effective impulse ground impedance of deeply driven ground rods combined with grounding grid or counterpoises with needles. The potential rises of the test ground electrodes were measured as a function of th...

      This paper describes the characteristics of effective impulse ground impedance of deeply driven ground rods combined with grounding grid or counterpoises with needles. The potential rises of the test ground electrodes were measured as a function of the rise time of applied impulse currents and the effective impulse ground impedances were calculated The impulse ground impedances of deeply driven ground rods strongly depend on the rise time of impulse currents and significantly reduced by the connection of grounding grids in parallel.

      더보기

      국문 초록 (Abstract)

      본 논문은 메쉬 접지전극이나 침부 매설지선이 연결된 심매설 봉상 접지전극의 실효임펄스접지임피던스의 특성을 다루었다. 시험용 접지전극의 전위상승은 인가된 임펄스 전류의 상승시간의 함수로 측정되었고, 실효임펄스접지 임피던스는 산출되었다. 심매설 봉상 접지전극의 임펄스접지임피던스는 임펄스 전류의 상승시간에 강하게 의존하며 메쉬 접지전각과의 병렬연결에 의해 확연히 감소하였다.
      번역하기

      본 논문은 메쉬 접지전극이나 침부 매설지선이 연결된 심매설 봉상 접지전극의 실효임펄스접지임피던스의 특성을 다루었다. 시험용 접지전극의 전위상승은 인가된 임펄스 전류의 상승시간...

      본 논문은 메쉬 접지전극이나 침부 매설지선이 연결된 심매설 봉상 접지전극의 실효임펄스접지임피던스의 특성을 다루었다. 시험용 접지전극의 전위상승은 인가된 임펄스 전류의 상승시간의 함수로 측정되었고, 실효임펄스접지 임피던스는 산출되었다. 심매설 봉상 접지전극의 임펄스접지임피던스는 임펄스 전류의 상승시간에 강하게 의존하며 메쉬 접지전각과의 병렬연결에 의해 확연히 감소하였다.

      더보기

      참고문헌 (Reference)

      1 "조합형 써지전압ㆍ전류발생기의 제작과 특성" c : 1876-1878, 1996.7.

      2 "Transient Performance of Grounding Grids" pp.2053~2058 : -4, 1989.

      3 "Transient Impedance of GIS Grounding Grid" PD-10 (PD-10): 723-738, 1995

      4 "Transient Ground Potential Rise in Gas-Insulated Substations-Experimental Studies" pas-101 (pas-101): 1982-, pp.3603-3609

      5 "Sensitivity Analysis of Experimentally Determined Grounding Grid Impulse Characteristics" pd-13 (pd-13): 1136-1141, 1998.

      6 "Resistance of Grounding Systems Stationary and Transient Behavior" 6715-, 1995.9.

      7 "Impulse Impedance of Grounding Grids" no.6 : 214-218, 1980.

      8 "IEEE Guide for Measurement of Impedance and Safety Characteristics of Large Extended or Interconnected Grounding Systems" 1731-, 1991.

      9 "Experimental Investigations of Transient Impedances of Some Grounding Systems" 237-240, 1997.

      10 "A Part of Grounding for Lightning Protection Technique" 9 : 671676-, 1989.9.

      1 "조합형 써지전압ㆍ전류발생기의 제작과 특성" c : 1876-1878, 1996.7.

      2 "Transient Performance of Grounding Grids" pp.2053~2058 : -4, 1989.

      3 "Transient Impedance of GIS Grounding Grid" PD-10 (PD-10): 723-738, 1995

      4 "Transient Ground Potential Rise in Gas-Insulated Substations-Experimental Studies" pas-101 (pas-101): 1982-, pp.3603-3609

      5 "Sensitivity Analysis of Experimentally Determined Grounding Grid Impulse Characteristics" pd-13 (pd-13): 1136-1141, 1998.

      6 "Resistance of Grounding Systems Stationary and Transient Behavior" 6715-, 1995.9.

      7 "Impulse Impedance of Grounding Grids" no.6 : 214-218, 1980.

      8 "IEEE Guide for Measurement of Impedance and Safety Characteristics of Large Extended or Interconnected Grounding Systems" 1731-, 1991.

      9 "Experimental Investigations of Transient Impedances of Some Grounding Systems" 237-240, 1997.

      10 "A Part of Grounding for Lightning Protection Technique" 9 : 671676-, 1989.9.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2015-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2014-01-08 학술지명변경 외국어명 : 미등록 -> Journal of the Korean Institute of Illuminating and Electrical Installation Engineers KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.17 0.17 0.19
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.18 0.17 0.342 0.05
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼