RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기

    Iris 전송손실 측정값을 이용한 이중모드 협대역 도파관 채널여파기의 설계 및 제작 = Design and implementation of dual-mode narrow-band waveguide channel filter using measured iris transmission loss data

    한글로보기

    https://www.riss.kr/link?id=A106789335

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    In this paper, measured iris transmission loss data and simulated data by using 3-dimension full-wave analysis S/W are presented and compared with Marcuvitz's theory. And by using measured iris data, dual-mode narrow-band channel filters can be successfully implemented. This paper shows that there is severe difference between the transmission loss of iris calculated by using Marcuvitz's equation to calculate iris dimension, if the length of slot iris is longer than .lambda./.pi., and in the long urn the response of channel filter is distorted. Experimental result shows that the characteristic response of implemented channel filter by using the iris transmission loss graph presented here matches well the design specfications. In conclusion, iris transmission loss measurement method will be very useful to design channel filter.
    번역하기

    In this paper, measured iris transmission loss data and simulated data by using 3-dimension full-wave analysis S/W are presented and compared with Marcuvitz's theory. And by using measured iris data, dual-mode narrow-band channel filters can be succ...

    In this paper, measured iris transmission loss data and simulated data by using 3-dimension full-wave analysis S/W are presented and compared with Marcuvitz's theory. And by using measured iris data, dual-mode narrow-band channel filters can be successfully implemented. This paper shows that there is severe difference between the transmission loss of iris calculated by using Marcuvitz's equation to calculate iris dimension, if the length of slot iris is longer than .lambda./.pi., and in the long urn the response of channel filter is distorted. Experimental result shows that the characteristic response of implemented channel filter by using the iris transmission loss graph presented here matches well the design specfications. In conclusion, iris transmission loss measurement method will be very useful to design channel filter.

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼