      원자력발전소 안전계통 소프트웨어의 확인/검증을 위한 시험장치 개발에 관한 연구 = A Study on the Development of Test Facility for Safety System Software V/V in Nuclear Power Plant

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      The use of computers as part of nuclear safety systems elicits additional requirements-software verification and validation (v/v), hardware qualification-not specifically addressed in general industry fields. The computer used in nuclear power plants is a system that includes computer hardware, software, firmware, and interfaces. To develop the computer systems graded with nuclear safety class, the developing environments have to be required in advance and the developed software have to be verified and validated in accordance with nuclear code and standards. With this requirements, the test facility for Inadequate Core Cooling Monitoring System (ICCMS) as one of safety systems in the nuclear power plants was developed. The test facility consists of three(3) parts such as Input/Output (I/O) simulator, Plant Data Acqusition System (PDAS) cabinets and supervisory computer. The performance of the system was validated by manual test procedure.
      번역하기

      The use of computers as part of nuclear safety systems elicits additional requirements-software verification and validation (v/v), hardware qualification-not specifically addressed in general industry fields. The computer used in nuclear power plants ...

      The use of computers as part of nuclear safety systems elicits additional requirements-software verification and validation (v/v), hardware qualification-not specifically addressed in general industry fields. The computer used in nuclear power plants is a system that includes computer hardware, software, firmware, and interfaces. To develop the computer systems graded with nuclear safety class, the developing environments have to be required in advance and the developed software have to be verified and validated in accordance with nuclear code and standards. With this requirements, the test facility for Inadequate Core Cooling Monitoring System (ICCMS) as one of safety systems in the nuclear power plants was developed. The test facility consists of three(3) parts such as Input/Output (I/O) simulator, Plant Data Acqusition System (PDAS) cabinets and supervisory computer. The performance of the system was validated by manual test procedure.