RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재후보 SCOPUS

      미세각막절삭기를 이용한 라식 수술 시 각막절편 두께에 영향을 미치는 수술 전 인자 = Preoperative Factors related to Corneal Flap Thickness in LASIK using Microkeratome

      한글로보기

      https://www.riss.kr/link?id=A100522809

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To identify factors that may be related to variations in corneal flap thickness in LASIK using the Moria M2 microkeratome. Methods: The charts of patients having LASIK based on steep keratometry nomogram using Moria M2 microkeratome (head : 110 ?m) and excimer laser (VISX STAR S2, USA) in our department of ophthalmology from March, 2003, to May 2005, were reviewed retrospectively. A total of 195 eyes were enrolled in the investigation. We analyzed relationship between corneal flap thickness and preoperative factors including central corneal thickness, steep keratometer, corneal diameter, suction ring using multiple regression analysis. Results: Mean corneal flap thickness was 119.37±21.21 ?m. There was a statistically significant positive correlation between flap thickness and central corneal thickness (p<0.05). No correlation was found between flap thickness and other preoperative factors including steep keratometer, corneal diameter and suction ring. Conclusions: Mean corneal flap thickness using the Moria M2 110 ?m head was 119.37±21.21 ?m, little thicker than our expectation. When surgery is performed based on steep keratometry nomogram using Moria M2 microkeratome, if intraoperative factors are excluded, there is a trend toward thicker flap thickness with thicker central corneal thickness, whereas steep keratometer, corneal diameter or suction ring have no influence on flap thickness.
      번역하기

      Purpose: To identify factors that may be related to variations in corneal flap thickness in LASIK using the Moria M2 microkeratome. Methods: The charts of patients having LASIK based on steep keratometry nomogram using Moria M2 microkeratome (head : 1...

      Purpose: To identify factors that may be related to variations in corneal flap thickness in LASIK using the Moria M2 microkeratome. Methods: The charts of patients having LASIK based on steep keratometry nomogram using Moria M2 microkeratome (head : 110 ?m) and excimer laser (VISX STAR S2, USA) in our department of ophthalmology from March, 2003, to May 2005, were reviewed retrospectively. A total of 195 eyes were enrolled in the investigation. We analyzed relationship between corneal flap thickness and preoperative factors including central corneal thickness, steep keratometer, corneal diameter, suction ring using multiple regression analysis. Results: Mean corneal flap thickness was 119.37±21.21 ?m. There was a statistically significant positive correlation between flap thickness and central corneal thickness (p<0.05). No correlation was found between flap thickness and other preoperative factors including steep keratometer, corneal diameter and suction ring. Conclusions: Mean corneal flap thickness using the Moria M2 110 ?m head was 119.37±21.21 ?m, little thicker than our expectation. When surgery is performed based on steep keratometry nomogram using Moria M2 microkeratome, if intraoperative factors are excluded, there is a trend toward thicker flap thickness with thicker central corneal thickness, whereas steep keratometer, corneal diameter or suction ring have no influence on flap thickness.

      더보기

      참고문헌 (Reference)

      1 "The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis" 107 : 2140-2143, 2000

      2 "The Nidek MK-2000 microkeratome system" 17 : 250-251, 2001

      3 "The Consistency of corneal flap thickness and size in LASIK using the Innovatome automatic microkeratome" 41 : 1331-1336, 2000

      4 "Surgical instrument" Slack 35-68, 1998

      5 "Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome" 26 : 1729-1732, 2000

      6 "Reproducibility of corneal flap thickness in LASIK" 30 : 350-353, 1999

      7 "Microkeratome accuracy in LASIK" 108 : 1929-1930, 2001

      8 "Laser in situ keratomileusis to correct myopia of -6.00 to -29.00 diopters" 12 : 575-584, 1996

      9 "Keratomileusis in situ for high myopia" 22 : 1443-1450, 1996

      10 "Iatrogenic keratectasia after laser in situ keratomileusis" 14 : 312-317, 1998

      1 "The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis" 107 : 2140-2143, 2000

      2 "The Nidek MK-2000 microkeratome system" 17 : 250-251, 2001

      3 "The Consistency of corneal flap thickness and size in LASIK using the Innovatome automatic microkeratome" 41 : 1331-1336, 2000

      4 "Surgical instrument" Slack 35-68, 1998

      5 "Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome" 26 : 1729-1732, 2000

      6 "Reproducibility of corneal flap thickness in LASIK" 30 : 350-353, 1999

      7 "Microkeratome accuracy in LASIK" 108 : 1929-1930, 2001

      8 "Laser in situ keratomileusis to correct myopia of -6.00 to -29.00 diopters" 12 : 575-584, 1996

      9 "Keratomileusis in situ for high myopia" 22 : 1443-1450, 1996

      10 "Iatrogenic keratectasia after laser in situ keratomileusis" 14 : 312-317, 1998

      11 "Flap measurements with the Hansatome microkeratome" 18 : 149-154, 2002

      12 "Experimental evaluation of two current generation automated microkeratome:Hansatome and Supratome" 129 : 59-67, 2000

      13 "Experience with the Nidek MK-2000 microkeratome in 1220 cases" 17 : 252-254, 2001

      14 "Excimer laser in situ keratomileusis and photorefractive keratectomy for correction of high myopia" 10 : 498-510, 1994

      15 "Evaluation of the reliability of the Nidek MK-2000 microkeratome for laser in situ keratomileusis" 17 : 255-258, 2001

      16 "Corneal flap thickness in laser in situ keratomileusis using the Moria M2 microkeratome" 30 : 1902-1908, 2004

      17 "Corneal flap thickness in laser in situ keratomileusis using an SCMD manual microkeratome" 25 : 1087-1092, 1999

      18 "Corneal flap thickness according to suction time of microkeratome in porcine eye" 43 : 1133-1137, 2002

      19 "Corneal flap dimenstions in laser in situ keratomileusis using the Hansatome microkeratome" 26 : 1729-1932, 2000

      20 "Biomechanical properties of keratoconus and normal corneas" 31 : 435-41, 1980

      21 "Assembly of the microkeratome and personal LASIK principles and techniques" Slack 175-184, 1998

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.22 0.22 0.22
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.23 0.23 0.366 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼