The electric railway cars are operated by high voltage supply through the catenary wire. Also, numerous electric equipments operated by electric signal are distributed in the electric railway cars. Such electric equipments are exposed to EMI/EMC probl...
The electric railway cars are operated by high voltage supply through the catenary wire. Also, numerous electric equipments operated by electric signal are distributed in the electric railway cars. Such electric equipments are exposed to EMI/EMC problems, and there is the possibility that the magnetic field due to the catenary wire current takes effect on the electromagnetic field in the electric railway cars which move under the catenary wire. There is the possibility that the electromagnetic interference generates in view of the operation of many electric equipments in the electric railway cars. There is the possibility that the communication device faults generate, and that the hazards on the human beings generate. In this paper, we predict the magnetic field around the catenary wire, and obtain the exact magnetic field distribution by comparing the analytic results and the numerical results. Finally, we confirmed the possibility of the passive loop mitigation by comparing the analytic results and the numerical results through the passive loop mitigation technique.