RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Ultrasound-assisted chiral derivatization of etodolac with (1R)-(-)-menthyl chloroformate for the determination of etodolac enantiomers

      한글로보기

      https://www.riss.kr/link?id=A107492241

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>This study presents the first report of an ultrasound-assisted derivatization reaction between a carboxylic acid of etodolac (ETO) and a chiral derivatization reagent, (1R)-(-)-menthyl chloroformate (R-MCF). Fifty mu L of deproteinated mouse ...

      <P>This study presents the first report of an ultrasound-assisted derivatization reaction between a carboxylic acid of etodolac (ETO) and a chiral derivatization reagent, (1R)-(-)-menthyl chloroformate (R-MCF). Fifty mu L of deproteinated mouse serum containing ETO enantiomers was derivatized with 125 mu L of 200 mM R-MCF and 17 mu L of pyridine (a catalyst), with the reaction facilitated by ultrasonic radiation for 13 min, which were the optimal conditions as determined by response surface methodology. After quenching the reaction by adding an aqueous L-proline solution, the mixture was subjected to salting-out assisted liquid-liquid extraction (SA-LLE), which provided phase separation for sample concentration as well as cleanup. The ETO diastereomers were separated on a Phenomenex Gemini C-18 column (150 x 4.6 mm, 5 mu m) under a simple gradient elution of a mobile phase containing a mixture of methanol: acetonitrile (10: 1, V/V) and 10 mM acetic acid at a flow rate of 1.0 mL min(-1), followed by fluorescence detection with excitation and fluorescence emission wavelengths of 235 nm and 345 nm, respectively. The developed method was validated for specificity, sensitivity, linearity, accuracy, precision, stability, and matrix effect. A good linearity in the range of 0.5-50.0 mu g mL(-1) for each ETO enantiomer with r(2) > 0.998 and acceptable values for the intra-day and inter-day accuracy and precision as well as negligible matrix effects supported the suitability and reliability of the method. Finally, this method was used to analyze real samples taken from mice treated with (+/-)-ETO. (C) 2015 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼