RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      LOADED IMPLANT와 UNLOADED IMPLANT의 조직학적 비교 연구 = A HISTOLOGIC COMPARATIVE STUDY OF LOADED AND UNLOADED TITANIUM IMPLANTS

      한글로보기

      https://www.riss.kr/link?id=A100928284

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants were inserted. Some implants were functionally loaded through fixed detachable prosthesis and some are isolated and unloaded. The dog was sacrificed four months later and bone sections with implants were processed for histologic evaluation and the results were as follows ; (1) The bone to implant interface after four months of load bearing presented no mobility and no marginal bone loss radiographically and histologically. (2) The interface zone between compact bone and implant revealed a direct bone to implant contact and in some areas marrow tissue contacts were examined at the light microscopic level. (3) At the ultrastructural level the interface of surrounding compact bone matrix and implant, three types of superficial layers were found ; one with moderate electron dense amorphous granular substance layer, other with high electron dense fine granular substance layer, and another type of amorphous granular substance covered with high electron dense line of minute granules. (4) The osteoblasts in the marrow tissue neighboring implants and osteocytes in compact bone showed typical normal characteristics and in the marrow tissues some of lymphocytes and mast cells were observed. (5) The abscence of abnormal tissue reactions at a cellular level indicates a high degree of biocompatibility for the experimental titanium implant and basically no difference was found between functionally loaded and unloaded implants.
      번역하기

      In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants wer...

      In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants were inserted. Some implants were functionally loaded through fixed detachable prosthesis and some are isolated and unloaded. The dog was sacrificed four months later and bone sections with implants were processed for histologic evaluation and the results were as follows ; (1) The bone to implant interface after four months of load bearing presented no mobility and no marginal bone loss radiographically and histologically. (2) The interface zone between compact bone and implant revealed a direct bone to implant contact and in some areas marrow tissue contacts were examined at the light microscopic level. (3) At the ultrastructural level the interface of surrounding compact bone matrix and implant, three types of superficial layers were found ; one with moderate electron dense amorphous granular substance layer, other with high electron dense fine granular substance layer, and another type of amorphous granular substance covered with high electron dense line of minute granules. (4) The osteoblasts in the marrow tissue neighboring implants and osteocytes in compact bone showed typical normal characteristics and in the marrow tissues some of lymphocytes and mast cells were observed. (5) The abscence of abnormal tissue reactions at a cellular level indicates a high degree of biocompatibility for the experimental titanium implant and basically no difference was found between functionally loaded and unloaded implants.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼