RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재 SCIE SCOPUS

    Diagnostic Performance of Angiography-Derived FFR According to the Analysis Factors

    한글로보기

    https://www.riss.kr/link?id=A110163131

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Background and ObjectivesQuantitative flow ratio (QFR) is a method for estimating fractional flow reserve (FFR) without the use of an invasive pressure wire or hyperemic agent. However, the reasons for variation in QFR accuracy across studies and the factors associated with its accuracy remain unclear. The aim of this study was to investigate the diagnostic performance of QFR under different clinical and analysis conditions.


    MethodsThis multicenter trial prospectively enrolled patients undergoing coronary angiography with an indication for invasive FFR. The composite score for the QFR analysis factors was calculated based on the presence or absence of the angiographic factor, system factor, lesion factor, and subjective difficulty factor. The diagnostic performance of the QFR was assessed for each composite score using FFR ≤0.80 as the reference.


    ResultsA total of 285 vessels from 239 patients were analyzed. The median FFR and QFR values were 0.83 (interquartile range [IQR], 0.78–0.88) and 0.83 (IQR, 0.76–0.89), respectively. Using FFR ≤0.80 as a reference, QFR showed an overall diagnostic accuracy of 81.4%. Higher composite scores were associated with lower diagnostic performance of QFR in predicting FFR ≤0.80 (p-for-trend=0.010). The diagnostic accuracy of QFR ranged from 94.1% in vessels with low composite scores to 73.7% in those with high composite scores.


    ConclusionsThe diagnostic accuracy of QFR decreases with increasing lesion complexity, system factors, lower angiographic image quality, and analysis difficulty. These findings suggest that specific lesion, system, and imaging-related factors can significantly impact the reliability of QFR in clinical practice.
    번역하기

    Background and ObjectivesQuantitative flow ratio (QFR) is a method for estimating fractional flow reserve (FFR) without the use of an invasive pressure wire or hyperemic agent. However, the reasons for variation in QFR accuracy across studies and the ...

    Background and ObjectivesQuantitative flow ratio (QFR) is a method for estimating fractional flow reserve (FFR) without the use of an invasive pressure wire or hyperemic agent. However, the reasons for variation in QFR accuracy across studies and the factors associated with its accuracy remain unclear. The aim of this study was to investigate the diagnostic performance of QFR under different clinical and analysis conditions.


    MethodsThis multicenter trial prospectively enrolled patients undergoing coronary angiography with an indication for invasive FFR. The composite score for the QFR analysis factors was calculated based on the presence or absence of the angiographic factor, system factor, lesion factor, and subjective difficulty factor. The diagnostic performance of the QFR was assessed for each composite score using FFR ≤0.80 as the reference.


    ResultsA total of 285 vessels from 239 patients were analyzed. The median FFR and QFR values were 0.83 (interquartile range [IQR], 0.78–0.88) and 0.83 (IQR, 0.76–0.89), respectively. Using FFR ≤0.80 as a reference, QFR showed an overall diagnostic accuracy of 81.4%. Higher composite scores were associated with lower diagnostic performance of QFR in predicting FFR ≤0.80 (p-for-trend=0.010). The diagnostic accuracy of QFR ranged from 94.1% in vessels with low composite scores to 73.7% in those with high composite scores.


    ConclusionsThe diagnostic accuracy of QFR decreases with increasing lesion complexity, system factors, lower angiographic image quality, and analysis difficulty. These findings suggest that specific lesion, system, and imaging-related factors can significantly impact the reliability of QFR in clinical practice.

    더보기

    동일학술지(권/호) 다른 논문

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼