RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기

    초음파에 의한 액체 미립화 입경 분포도에 관한 연구 = A Study on Size Distributions of the Liquid Atomization by Ultrasonic

    한글로보기

    https://www.riss.kr/link?id=A2015149

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    A Study on size distributions of the liquid atomization by ultrasonic was carried out using 3 methods, such as direct vibration, aerosol and improvement method. Distilled water and city water were selected as the reference liquids and gasoline, kerosene and petroleum as fuel liquids.
    Two kinds of ultrasonic transducers, with 28kHz and 2MHz were used. Characteristics and phenomena on ultrasonic atomization were observed and examined relatively according to influx and liquid load by using the Malvern system. In results, The best uniformity of particle size was achieved by the direct vibration method, and their mean size was 10 times larger than that of the aerosol method.
    번역하기

    A Study on size distributions of the liquid atomization by ultrasonic was carried out using 3 methods, such as direct vibration, aerosol and improvement method. Distilled water and city water were selected as the reference liquids and gasoline, kero...

    A Study on size distributions of the liquid atomization by ultrasonic was carried out using 3 methods, such as direct vibration, aerosol and improvement method. Distilled water and city water were selected as the reference liquids and gasoline, kerosene and petroleum as fuel liquids.
    Two kinds of ultrasonic transducers, with 28kHz and 2MHz were used. Characteristics and phenomena on ultrasonic atomization were observed and examined relatively according to influx and liquid load by using the Malvern system. In results, The best uniformity of particle size was achieved by the direct vibration method, and their mean size was 10 times larger than that of the aerosol method.

    더보기

    동일학술지(권/호) 다른 논문

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼