      Evaluation report on the causal association between humidifier disinfectants and lung injury

      한글로보기

      https://www.riss.kr/link?id=A105524283

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      OBJECTIVES: As of November 2011, the Korean government recalled and banned humidifier disinfectants (HDs) from the market, because four case-control studies and one retrospective epidemiological study proved the association between HDs and lung injury...

      OBJECTIVES: As of November 2011, the Korean government recalled and banned humidifier disinfectants (HDs) from the market, because four case-control studies and one retrospective epidemiological study proved the association between HDs and lung injury of unknown cause. The report reviewed the causal role of HDs in lung injury based on scientific evidences.
      METHODS: A careful examination on the association between the HDs and lung injury was based on the criteria of causality inference by Hill and the US Surgeon General Expert Committee.
      RESULTS: We found that all the evidences on the causality fulfilled the criteria (strength of association, consistency, specificity, temporality, biologic gradient, plausibility, coherence, experiment, analogy, consideration of alternative explanations, and cessation of exposure), which proved the unknown cause lung injury reported in 2011 was caused by the HDs. In particular, there was no single reported case of lung injury since the ban in selling HDs in November 2011 as well as before the HDs were sold in markets.
      CONCLUSIONS: Although only a few epidemiological studies in Korea have evaluated the association between lung injury and the use of HDs, those studies contributed to proving the strong association between the use of the HDs and lung injury, based on scientific evidence.

      더보기

      참고문헌 (Reference)

      1 Kim YH, "Transforming growth factor-beta 1 in humidifier disinfectant-associated children’s interstitial lung disease" 51 : 173-182, 2016

      2 홍수종, "Toxic Inhalational Injury-Associated Interstitial Lung Disease in Children" 대한의학회 28 (28): 915-923, 2013

      3 Hill AB, "The environment and disease: association or causation?" 58 : 295-300, 1965

      4 Lung Injury Investigation Committee, "Report of the incidence of humidifier disinfectant-associated damages" Han Rim Won Publishing 39-, 2014

      5 Park DU, "Relationship between exposure to household humidifier disinfectants and risk of lung injury: a family-based study" 10 : e0124610-, 2015

      6 Paek D, "Nationwide study of humidifier disinfectant lung injury in South Korea, 1994-2011. Incidence and dose-response relationships" 12 : 1813-1821, 2015

      7 Daftary AS, "Inhalational lung injury associated with humidifier “white dust”" 127 : e509-e512, 2011

      8 Yang HJ, "Inhalation toxicity of humidifier disinfectants as a risk factor of children’s interstitial lung disease in Korea: a case-control study" 8 : e64430-, 2013

      9 "Humidifier fever: a disease to look out for" 1 : 1164-, 1978

      10 Park JH, "Humidifier disinfectants are a cause of lung injury among adults in South Korea: a community-based case-control study" 11 : e0151849-, 2016

      1 Kim YH, "Transforming growth factor-beta 1 in humidifier disinfectant-associated children’s interstitial lung disease" 51 : 173-182, 2016

      2 홍수종, "Toxic Inhalational Injury-Associated Interstitial Lung Disease in Children" 대한의학회 28 (28): 915-923, 2013

      3 Hill AB, "The environment and disease: association or causation?" 58 : 295-300, 1965

      4 Lung Injury Investigation Committee, "Report of the incidence of humidifier disinfectant-associated damages" Han Rim Won Publishing 39-, 2014

      5 Park DU, "Relationship between exposure to household humidifier disinfectants and risk of lung injury: a family-based study" 10 : e0124610-, 2015

      6 Paek D, "Nationwide study of humidifier disinfectant lung injury in South Korea, 1994-2011. Incidence and dose-response relationships" 12 : 1813-1821, 2015

      7 Daftary AS, "Inhalational lung injury associated with humidifier “white dust”" 127 : e509-e512, 2011

      8 Yang HJ, "Inhalation toxicity of humidifier disinfectants as a risk factor of children’s interstitial lung disease in Korea: a case-control study" 8 : e64430-, 2013

      9 "Humidifier fever: a disease to look out for" 1 : 1164-, 1978

      10 Park JH, "Humidifier disinfectants are a cause of lung injury among adults in South Korea: a community-based case-control study" 11 : e0151849-, 2016

      11 Hyun Jung Koo, "Humidifier disinfectant-associated lung injury in adults: Prognostic factors in predicting short-term outcome" Springer Nature America, Inc 27 (27): 203-211,

      12 Park S, "Humidifier disinfectant-associated interstitial lung disease in an animal model induced by polyhexamethylene guanidine aerosol" 190 : 706-708, 2014

      13 Nemery B, "Humidifier disinfectant-associated interstitial lung disease and the Ardystil syndrome" 191 : 116-117, 2015

      14 Yoon HM, "Humidifier disinfectant-associated children’s interstitial lung disease: computed tomographic features, histopathologic correlation and comparison between survivors and non-survivors" 26 : 235-243, 2016

      15 Kim KW, "Humidifier disinfectant-associated children’s interstitial lung disease" 189 : 48-56, 2014

      16 Szklo M, "Epidemiology: beyond the basics" Jones & Bartlett Learning 155-, 2014

      17 Gordis L, "Epidemiology" Elsevier 248-253, 2014

      18 Höfler M, "Causal inference based on counterfactuals" 5 : 28-, 2005

      19 Kim JY, "Acute cardiovascular toxicity of sterilizers, PHMG, and PGH: severe inflammation in human cells and heart failure in zebrafish" 13 : 148-160, 2013

      20 Kim HJ, "A cluster of lung injury cases associated with home humidifier use : an epidemiological investigation" 69 : 703-708, 2014

      21 Hong SB, "A cluster of lung injury associated with home humidifier use: clinical, radiological and pathological description of a new syndrome" 69 : 694-702, 2014

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2021-01-01 평가 등재학술지 선정 (해외등재 학술지 평가) KCI등재
      2020-12-01 평가 등재 탈락 (해외등재 학술지 평가)
      2018-08-07 학술지명변경 외국어명 : Korean Journal of Epidemiology -> Epidemiology and Health KCI등재
      2017-12-01 평가 SCOPUS 등재 (기타) KCI등재
      2013-12-01 평가 등재후보 탈락 (등재후보2차)
      2012-01-01 평가 등재후보 1차 FAIL (기타) KCI등재후보
      2010-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2009-10-12 학술지명변경 한글명 : 한국역학회지 -> Epidemiology and Health
      외국어명 : Korean Journal of Epidemiology -> 미등록
      2006-07-21 학회명변경 영문명 : Korean Epidemiological Society -> Korean Society of Epidemiology
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼