In this paper, the scattered electric fields is computed to predict the shielding zone by analysing the effect of the reflected azimuth anlge at the building, and considering the path differences at observation point between the rays from origin and a...
In this paper, the scattered electric fields is computed to predict the shielding zone by analysing the effect of the reflected azimuth anlge at the building, and considering the path differences at observation point between the rays from origin and any point in the building. The scattering coefficients. which are applicable to the prediction of shielding zone. are computed and compared with measured one. We found that the scattering power become weak over 10 degree of the azimuth angle at which the scattering coefficient is lower than 40 dB. From this, the shielding zone can be estimated.