      EHD In-tube 유동비등 열전달 특성에 대한 실험적 연구 = Experimental study on in-tube flow boiling heat transfer enhancement using an electric field

      한글로보기

      https://www.riss.kr/link?id=E805134

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      An experimental study on evaporative heat transfer characteristics in a micro-fin tube has been performed. The micro-fin tube with outer diameter of 9.52 mm was used as teat section, and it was heated by applying hot liquid to the test tube. The refrigerant v as R-22 and the tube-circular electrode system was used. The DC voltage was applied to the circular electrode, while the tube was grounded. Experiments were conducted at mass fluxes of 50kg/m²s, 100kg/m²s, and heat flux of 5kW/m². For each mass flux condition, evaporation temperature was set at 5°C. The inlet quality was changed from 0 to 0.5. The results showed the enhancement of the evaporative heat transfer cnefficient of the tube was largely increased under the high voltage, compared with that of the normal condition(0kV), With increasing the mass flux and inlet quality, the pressure drop increased linearly.
      번역하기

      An experimental study on evaporative heat transfer characteristics in a micro-fin tube has been performed. The micro-fin tube with outer diameter of 9.52 mm was used as teat section, and it was heated by applying hot liquid to the test tube. The refri...

      An experimental study on evaporative heat transfer characteristics in a micro-fin tube has been performed. The micro-fin tube with outer diameter of 9.52 mm was used as teat section, and it was heated by applying hot liquid to the test tube. The refrigerant v as R-22 and the tube-circular electrode system was used. The DC voltage was applied to the circular electrode, while the tube was grounded. Experiments were conducted at mass fluxes of 50kg/m²s, 100kg/m²s, and heat flux of 5kW/m². For each mass flux condition, evaporation temperature was set at 5°C. The inlet quality was changed from 0 to 0.5. The results showed the enhancement of the evaporative heat transfer cnefficient of the tube was largely increased under the high voltage, compared with that of the normal condition(0kV), With increasing the mass flux and inlet quality, the pressure drop increased linearly.

      더보기

      목차 (Table of Contents)

      • 1. 서론
      • 2. EHD 관내 증발열전달 실험
      • 2.1 실험장치
      • 2.2 실험방법
      • 3. Data Reduction
      • 1. 서론
      • 2. EHD 관내 증발열전달 실험
      • 2.1 실험장치
      • 2.2 실험방법
      • 3. Data Reduction
      • 4. 실험결과 및 고찰
      • 5. 결론
      • 참고문헌