RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Numerical and experimental study on biased tube temperature problem in tangential firing boiler

      한글로보기

      https://www.riss.kr/link?id=A107741875

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P> <P>In this study, a numerical and experimental investigation on the flow field in a 500-MW unit of a tangentially fired boiler has been performed to understand the effect of residual swirl on the t...

      <P><B>Abstract</B></P> <P>In this study, a numerical and experimental investigation on the flow field in a 500-MW unit of a tangentially fired boiler has been performed to understand the effect of residual swirl on the temperature distribution and inconsistency of flow velocity in the crossover pass. The k–k<SUB>L</SUB>–ω turbulence model was used in this study to analyse the possible formation of transition flow in the tangential firing boiler. Furthermore, 1D and 3D hybrid modelling were used for the simulation of the convective heat transfer in the boiler tube assembly. The commercially available code ANSYS Fluent and COMSOL were used for the studies, respectively. The numerical results for the velocity profile and residual swirl in the boiler were validated using the experimental results from the cold air velocity test, in which the flow velocity was directly measured in the full-scale boiler. The computational results agreed well with the experimental findings. Furthermore, from a comparison of the simulation and experiment, it was found that the biased gas flow induces non-uniform tube temperatures at the crossover pass area of the tangential firing boiler. These results aid in the detailed study of the residual swirl effects on the temperature or flue gas at various locations of the boiler. This study indicates that a non-uniform tube temperature at the crossover pass is an inherent problem resulting from residual swirl in the tangential firing boiler. Therefore, the pulverised coal burner should be fine-tuned to avoid tube rupture due to local overheating.</P> <P><B>Highlights</B></P> <P> <UL> <LI> A full-scale CFD simulation was performed for a 500-MW unit of a tangentially fired boiler to determine the flow behaviour. </LI> <LI> The CFD model was validated with experimental results from the cold air velocity test. </LI> <LI> Temperatures of the boiler tube were measured directly in commercial tangential firing boilers. </LI> <LI> Biased temperature profile of the steam and tube is attributed to the non-uniform velocity of the flue gas. </LI> </UL> </P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼