      Simplified Method to Measure the Peripapillary Choroidal Thickness Using Three-dimensional Optical Coherence Tomography

      한글로보기

      https://www.riss.kr/link?id=A103853137

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To evaluate a simplified method to measure peripapillary choroidal thickness using commercially available, three-dimensional optical coherence tomography (3D-OCT).
      Methods: 3D-OCT images of normal eyes were consecutively obtained from the 3D-OCT database of Korea University Medical Center On the peripapillary images for retinal nerve fiber layer (RNFL) analysis,choroidal thickness was measured by adjusting the segmentation line for the retinal pigment epithelium to the chorioscleral junction using the modification tool built into the 3D-OCT image viewer program. Variations of choroidal thickness at 12 sectors of the peripapillary area were evaluated.
      Results: We were able to measure the peripapillary choroidal thickness in 40 eyes of our 40 participants, who had a mean age of 41.2 years (range, 15 to 84 years). Choroidal thickness measurements had strong interobserver correlation at each sector (r = 0.901 to 0.991, p < 0.001). The mean choroidal thickness was 191 ±62 μm. Choroidal thickness was greatest at the temporal quadrant (mean ± SD, 210 ± 78 μm), followed by the superior (202 ± 66 μm), nasal (187 ± 64 μm), and inferior quadrants (152 ± 59 μm).
      Conclusions: The measurement of choroidal thickness on peripapillary circle scan images for RNFL analysis using the 3D-OCT viewing program was highly reliable and efficient.
      번역하기

      Purpose: To evaluate a simplified method to measure peripapillary choroidal thickness using commercially available, three-dimensional optical coherence tomography (3D-OCT). Methods: 3D-OCT images of normal eyes were consecutively obtained from the 3D-...

      Purpose: To evaluate a simplified method to measure peripapillary choroidal thickness using commercially available, three-dimensional optical coherence tomography (3D-OCT).
      Methods: 3D-OCT images of normal eyes were consecutively obtained from the 3D-OCT database of Korea University Medical Center On the peripapillary images for retinal nerve fiber layer (RNFL) analysis,choroidal thickness was measured by adjusting the segmentation line for the retinal pigment epithelium to the chorioscleral junction using the modification tool built into the 3D-OCT image viewer program. Variations of choroidal thickness at 12 sectors of the peripapillary area were evaluated.
      Results: We were able to measure the peripapillary choroidal thickness in 40 eyes of our 40 participants, who had a mean age of 41.2 years (range, 15 to 84 years). Choroidal thickness measurements had strong interobserver correlation at each sector (r = 0.901 to 0.991, p < 0.001). The mean choroidal thickness was 191 ±62 μm. Choroidal thickness was greatest at the temporal quadrant (mean ± SD, 210 ± 78 μm), followed by the superior (202 ± 66 μm), nasal (187 ± 64 μm), and inferior quadrants (152 ± 59 μm).
      Conclusions: The measurement of choroidal thickness on peripapillary circle scan images for RNFL analysis using the 3D-OCT viewing program was highly reliable and efficient.

      더보기

      참고문헌 (Reference)

      1 Hood DC, "Structure versus function in glaucoma: an application of a linear model" 48 : 3662-3668, 2007

      2 Ehrlich JR, "Peripapillary choroidal thickness in glaucoma measured with optical coherence tomography" 92 : 189-194, 2011

      3 Danesh-Meyer HV, "Optic disc morphology in open-angle glaucoma compared with anterior ischemic optic neuropathies" 51 : 2003-2010, 2010

      4 Contreras I, "Optic disc evaluation by optical coherence tomography in nonarteritic anterior ischemic optic neuropathy" 48 : 4087-4092, 2007

      5 Contreras I, "Follow-up of nonarteritic anterior ischemic optic neuropathy with optical coherence tomography" 114 : 2338-2344, 2007

      6 Spaide RF, "Enhanced depth imaging spectral-domain optical coherence tomography" 146 : 496-500, 2008

      7 Fujiwara T, "Enhanced depth imaging optical coherence tomography of the choroid in highly myopic eyes" 148 : 445-450, 2009

      8 Maul EA, "Choroidal thickness measured by spectral domain optical coherence tomography: factors affecting thickness in glaucoma patients" 118 : 1571-1579, 2011

      9 Manjunath V, "Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography" 150 : 325-329, 2010

      10 Ikuno Y, "Choroidal thickness in healthy Japanese subjects" 51 : 2173-2176, 2010

      1 Hood DC, "Structure versus function in glaucoma: an application of a linear model" 48 : 3662-3668, 2007

      2 Ehrlich JR, "Peripapillary choroidal thickness in glaucoma measured with optical coherence tomography" 92 : 189-194, 2011

      3 Danesh-Meyer HV, "Optic disc morphology in open-angle glaucoma compared with anterior ischemic optic neuropathies" 51 : 2003-2010, 2010

      4 Contreras I, "Optic disc evaluation by optical coherence tomography in nonarteritic anterior ischemic optic neuropathy" 48 : 4087-4092, 2007

      5 Contreras I, "Follow-up of nonarteritic anterior ischemic optic neuropathy with optical coherence tomography" 114 : 2338-2344, 2007

      6 Spaide RF, "Enhanced depth imaging spectral-domain optical coherence tomography" 146 : 496-500, 2008

      7 Fujiwara T, "Enhanced depth imaging optical coherence tomography of the choroid in highly myopic eyes" 148 : 445-450, 2009

      8 Maul EA, "Choroidal thickness measured by spectral domain optical coherence tomography: factors affecting thickness in glaucoma patients" 118 : 1571-1579, 2011

      9 Manjunath V, "Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography" 150 : 325-329, 2010

      10 Ikuno Y, "Choroidal thickness in healthy Japanese subjects" 51 : 2173-2176, 2010

      11 Shin JW, "Choroidal thickness and volume mapping by a six radial scan protocol on spectraldomain optical coherence tomography" 119 : 1017-1023, 2012

      12 Tanabe H, "Choroid is thinner in inferior region of optic disks of normal eyes" 32 : 134-139, 2012

      13 Ho J, "Analysis of normal peripapillary choroidal thickness via spectral domain optical coherence tomography" 118 : 2001-2007, 2011

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2021-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2020-01-01 평가 등재학술지 선정 (재인증) KCI등재
      2019-12-01 평가 등재후보로 하락 (계속평가) KCI등재후보
      2010-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2009-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2007-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.11 0.11 0.12
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.1 0.13 0.482 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼