      건물일체형 지열히트펌프시스템의 난방 성능 분석 = Heating Performance Analysis of Building Integrated Geothermal System

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump ' Coefficient of performance(COP) of the heat pump was calculated . As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.
      번역하기

      Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose o...

      Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump ' Coefficient of performance(COP) of the heat pump was calculated . As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 실험 개요
      • 3. 난방 실험
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 실험 개요
      • 3. 난방 실험
      • 4. 결론
      • 후기
      • 참고문헌
      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼