RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      치과용 임플란트 식립 후 초기 적외선, 초음파 자극치료에 따른 골유착 변화에 관한 연구 = Study on Changes in Osseointegration Following Early Infrared and Ultrasonic Stimulation Treatment After Dental Implant Placement

      한글로보기

      https://www.riss.kr/link?id=A109324148

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      In this study, 3 dental implants were implanted in each femur of NZW rabbits, and only the right experimental group was irradiated with 850 nm infrared and 3 MHz ultrasonic waves for 10 minutes every day. After 3 and 6 weeks, a torsional test was performed using a universal testing machine to determine the changes in osseointegration. As a result, in the specimen subjected to 3 weeks, the maximum value of 3.01 MPa was measured in specimen #1, and the minimum value of 1.20 MPa was measured in specimen #1. In the control group, the maximum value of 0.75 MPa was measured in specimen #6, and the minimum value of 0.10 MPa was measured in specimen #4. The average value of specimens #1 to #3 of the experimental group was 1.76 MPa, and the average value of specimens #4 to #6 of the control group was 0.48 MPa. In the third week, among the torsion test results, for the control group, specimens #4 to #6, the specimen with the lowest initial osseointegration progress was measured at 0.10 MPa, and all of the measurement values at a total of 9 sites, including 3 sites for each specimen, were measured below 1.0 MPa. This is a very key part of this study, indicating that the initial osseointegration was very low. On the other hand, for the experimental group specimens #1 to #3, all of the measurement values at a total of 9 sites were measured above 1.0 MPa, and the maximum value was 3.01 MPa, confirming that 850 nm infrared light irradiation and 3 MHz ultrasound irradiation have an effect on improving osseointegration and bone quality with dental implants.
      번역하기

      In this study, 3 dental implants were implanted in each femur of NZW rabbits, and only the right experimental group was irradiated with 850 nm infrared and 3 MHz ultrasonic waves for 10 minutes every day. After 3 and 6 weeks, a to...

      In this study, 3 dental implants were implanted in each femur of NZW rabbits, and only the right experimental group was irradiated with 850 nm infrared and 3 MHz ultrasonic waves for 10 minutes every day. After 3 and 6 weeks, a torsional test was performed using a universal testing machine to determine the changes in osseointegration. As a result, in the specimen subjected to 3 weeks, the maximum value of 3.01 MPa was measured in specimen #1, and the minimum value of 1.20 MPa was measured in specimen #1. In the control group, the maximum value of 0.75 MPa was measured in specimen #6, and the minimum value of 0.10 MPa was measured in specimen #4. The average value of specimens #1 to #3 of the experimental group was 1.76 MPa, and the average value of specimens #4 to #6 of the control group was 0.48 MPa. In the third week, among the torsion test results, for the control group, specimens #4 to #6, the specimen with the lowest initial osseointegration progress was measured at 0.10 MPa, and all of the measurement values at a total of 9 sites, including 3 sites for each specimen, were measured below 1.0 MPa. This is a very key part of this study, indicating that the initial osseointegration was very low. On the other hand, for the experimental group specimens #1 to #3, all of the measurement values at a total of 9 sites were measured above 1.0 MPa, and the maximum value was 3.01 MPa, confirming that 850 nm infrared light irradiation and 3 MHz ultrasound irradiation have an effect on improving osseointegration and bone quality with dental implants.

      더보기

      참고문헌 (Reference)

      1 Tang CH, "Ultrasound induces hypoxia-inducible factor-1activation and inducible nitric-oxide synthase expression through the integrin/in- tegrin-linked kinase/Akt/mammalian target of rapamycin pathway in osteoblasts" 282 : 25406-25415, 2007

      2 Duarte LR, "The stimulation of bone growth by ultrasound" 101 : 153-159, 1983

      3 Zarb GA, "The longitudinal clinical ef- fectiveness of osseointegrated dental implants:the Toronto study. Part III: problems and complica- tions encountered" 64 : 185-194, 1990

      4 김지환 ; 정문규 ; 문홍석 ; 한동후, "The influence of Collar design on peri-implant marginal bone tissue" 46 : 53-64, 2008

      5 김성회 ; 김선재 ; 이근우 ; 한동후, "The effects of local factors on the survival of dental implants : A 19-year retrospective study" 48 : 28-40, 2010

      6 Machen MS, "The effect of low intensity pulsed ultrasound on regenerate bone in a less- than-rigid biomechanical environment" 12 : 239-247, 2002

      7 Krennmair G, "Single-tooth re-placement with the Frialit-2system : a retrospective clinical analy-sis of 146 implants" 17 : 78-85, 2002

      8 Kim YK, "Short-term retrospective clinical Study of Osstem . GS II, US III, SS III Implants" 12 : 12-22, 2008

      9 홍지연 ; 채경준 ; 정의원 ; 김창성 ; 조규성 ; 채중규 ; 김종관 ; 최성호, "Retrospective studies of dental implant placement at each intraoral site and situation" 37 : 805-824, 2007

      10 Brånemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period" 16 : 1-132, 1977

      1 Tang CH, "Ultrasound induces hypoxia-inducible factor-1activation and inducible nitric-oxide synthase expression through the integrin/in- tegrin-linked kinase/Akt/mammalian target of rapamycin pathway in osteoblasts" 282 : 25406-25415, 2007

      2 Duarte LR, "The stimulation of bone growth by ultrasound" 101 : 153-159, 1983

      3 Zarb GA, "The longitudinal clinical ef- fectiveness of osseointegrated dental implants:the Toronto study. Part III: problems and complica- tions encountered" 64 : 185-194, 1990

      4 김지환 ; 정문규 ; 문홍석 ; 한동후, "The influence of Collar design on peri-implant marginal bone tissue" 46 : 53-64, 2008

      5 김성회 ; 김선재 ; 이근우 ; 한동후, "The effects of local factors on the survival of dental implants : A 19-year retrospective study" 48 : 28-40, 2010

      6 Machen MS, "The effect of low intensity pulsed ultrasound on regenerate bone in a less- than-rigid biomechanical environment" 12 : 239-247, 2002

      7 Krennmair G, "Single-tooth re-placement with the Frialit-2system : a retrospective clinical analy-sis of 146 implants" 17 : 78-85, 2002

      8 Kim YK, "Short-term retrospective clinical Study of Osstem . GS II, US III, SS III Implants" 12 : 12-22, 2008

      9 홍지연 ; 채경준 ; 정의원 ; 김창성 ; 조규성 ; 채중규 ; 김종관 ; 최성호, "Retrospective studies of dental implant placement at each intraoral site and situation" 37 : 805-824, 2007

      10 Brånemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period" 16 : 1-132, 1977

      11 Wang FS, "Nitric oxide mediates ultrasound-induced hypoxia-inducible factor-1alpha activa- tion and vascular endothelial growth factor-A expression in human osteoblasts" 35 : 114-123, 2004

      12 Kim SG, "Multicenter retrospective clinical study of Osstem USII implant system in complete edentulous patients" 11 : 12-21, 2007

      13 Kondo T, "Low-intensity ultra- sound adjuvant therapy:enhancement of doxorubicin indu- ced cytotoxicity and the acoustic mechanisms involved" 36 : 61-68, 2009

      14 Romeo E, "Long-term survival and success of oral implants in the treatment of full and partial arches : a 7-year prospective study with the ITI dental implant system" 19 : 247-259, 2004

      15 Tuner J, "Laser therapy, Clinical Practice and Scientific Background; A guide for research scientists, doctors, dentists, veterianarians and other interested parties within the medical field" Prima Books AB 2-60, 2002

      16 Sawai Y, "Koto K : Effects of low-intensity pulsed ultrasound on osteosarcoma and cancer cells" 28 : 481-486, 2012

      17 Wennstro¨m JL, "Implant-supported single-tooth restorations : a 5-year prospec-tive study" 32 : 567-574, 2005

      18 Pounder NM, "Harrison AJ : Low intensity pulsed ultrasound for fracture healing : a review of the clinical evidence and the associated biological mechanism of action" 48 : 330-338, 2008

      19 Bergman B, "Evaluation of the results of treatment with osseointegrated implants by the Swedish National Board of Health and Welfare" 50 : 114-115, 1983

      20 황영섭 ; 전현준 ; 신상훈 ; 정인교 ; 김규천 ; 김철훈 ; 김욱규, "Effect of low intensity pulsed ultrasound (LIPUS) on bone healing around a titanium implant in the tibia of osteoporosis-induced rats" 37 : 386-395, 2011

      21 Albrektsson T, "Consensus report of session IV" Quintessence 365-369, 1993

      22 김영석 ; 이동근 ; 민승기 ; 이준 ; 문철, "Clini-cal study on success rate of osseointegrated dental implants" 24 : 137-147, 2002

      23 Esposito M, "Biological factors contributing to failures of os-seointegrated oral implants. (I). Success criteria and epidemiology" 106 : 527-551, 1998

      24 Esposito M, "A 5-year follow-up compara-tive analysis of the efficacy of various osseointe-grated dental implant systems : a systematic review of randomized controlled clinical trials" 20 : 557-568, 2005

      25 Adell R, "A 15-year study of osseointegrated implants in the reatment of the edentulous jaw" 10 : 387-416, 1981

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼