In this study, 3 dental implants were implanted in each femur of NZW rabbits, and only the right experimental group was irradiated with 850 nm infrared and 3 MHz ultrasonic waves for 10 minutes every day. After 3 and 6 weeks, a to...

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A109324148
2024
Korean
KCI등재
학술저널
1319-1326(8쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
In this study, 3 dental implants were implanted in each femur of NZW rabbits, and only the right experimental group was irradiated with 850 nm infrared and 3 MHz ultrasonic waves for 10 minutes every day. After 3 and 6 weeks, a to...
In this study, 3 dental implants were implanted in each femur of NZW rabbits, and only the right experimental group was irradiated with 850 nm infrared and 3 MHz ultrasonic waves for 10 minutes every day. After 3 and 6 weeks, a torsional test was performed using a universal testing machine to determine the changes in osseointegration. As a result, in the specimen subjected to 3 weeks, the maximum value of 3.01 MPa was measured in specimen #1, and the minimum value of 1.20 MPa was measured in specimen #1. In the control group, the maximum value of 0.75 MPa was measured in specimen #6, and the minimum value of 0.10 MPa was measured in specimen #4. The average value of specimens #1 to #3 of the experimental group was 1.76 MPa, and the average value of specimens #4 to #6 of the control group was 0.48 MPa. In the third week, among the torsion test results, for the control group, specimens #4 to #6, the specimen with the lowest initial osseointegration progress was measured at 0.10 MPa, and all of the measurement values at a total of 9 sites, including 3 sites for each specimen, were measured below 1.0 MPa. This is a very key part of this study, indicating that the initial osseointegration was very low. On the other hand, for the experimental group specimens #1 to #3, all of the measurement values at a total of 9 sites were measured above 1.0 MPa, and the maximum value was 3.01 MPa, confirming that 850 nm infrared light irradiation and 3 MHz ultrasound irradiation have an effect on improving osseointegration and bone quality with dental implants.
참고문헌 (Reference)
1 Tang CH, "Ultrasound induces hypoxia-inducible factor-1activation and inducible nitric-oxide synthase expression through the integrin/in- tegrin-linked kinase/Akt/mammalian target of rapamycin pathway in osteoblasts" 282 : 25406-25415, 2007
2 Duarte LR, "The stimulation of bone growth by ultrasound" 101 : 153-159, 1983
3 Zarb GA, "The longitudinal clinical ef- fectiveness of osseointegrated dental implants:the Toronto study. Part III: problems and complica- tions encountered" 64 : 185-194, 1990
4 김지환 ; 정문규 ; 문홍석 ; 한동후, "The influence of Collar design on peri-implant marginal bone tissue" 46 : 53-64, 2008
5 김성회 ; 김선재 ; 이근우 ; 한동후, "The effects of local factors on the survival of dental implants : A 19-year retrospective study" 48 : 28-40, 2010
6 Machen MS, "The effect of low intensity pulsed ultrasound on regenerate bone in a less- than-rigid biomechanical environment" 12 : 239-247, 2002
7 Krennmair G, "Single-tooth re-placement with the Frialit-2system : a retrospective clinical analy-sis of 146 implants" 17 : 78-85, 2002
8 Kim YK, "Short-term retrospective clinical Study of Osstem . GS II, US III, SS III Implants" 12 : 12-22, 2008
9 홍지연 ; 채경준 ; 정의원 ; 김창성 ; 조규성 ; 채중규 ; 김종관 ; 최성호, "Retrospective studies of dental implant placement at each intraoral site and situation" 37 : 805-824, 2007
10 Brånemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period" 16 : 1-132, 1977
1 Tang CH, "Ultrasound induces hypoxia-inducible factor-1activation and inducible nitric-oxide synthase expression through the integrin/in- tegrin-linked kinase/Akt/mammalian target of rapamycin pathway in osteoblasts" 282 : 25406-25415, 2007
2 Duarte LR, "The stimulation of bone growth by ultrasound" 101 : 153-159, 1983
3 Zarb GA, "The longitudinal clinical ef- fectiveness of osseointegrated dental implants:the Toronto study. Part III: problems and complica- tions encountered" 64 : 185-194, 1990
4 김지환 ; 정문규 ; 문홍석 ; 한동후, "The influence of Collar design on peri-implant marginal bone tissue" 46 : 53-64, 2008
5 김성회 ; 김선재 ; 이근우 ; 한동후, "The effects of local factors on the survival of dental implants : A 19-year retrospective study" 48 : 28-40, 2010
6 Machen MS, "The effect of low intensity pulsed ultrasound on regenerate bone in a less- than-rigid biomechanical environment" 12 : 239-247, 2002
7 Krennmair G, "Single-tooth re-placement with the Frialit-2system : a retrospective clinical analy-sis of 146 implants" 17 : 78-85, 2002
8 Kim YK, "Short-term retrospective clinical Study of Osstem . GS II, US III, SS III Implants" 12 : 12-22, 2008
9 홍지연 ; 채경준 ; 정의원 ; 김창성 ; 조규성 ; 채중규 ; 김종관 ; 최성호, "Retrospective studies of dental implant placement at each intraoral site and situation" 37 : 805-824, 2007
10 Brånemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period" 16 : 1-132, 1977
11 Wang FS, "Nitric oxide mediates ultrasound-induced hypoxia-inducible factor-1alpha activa- tion and vascular endothelial growth factor-A expression in human osteoblasts" 35 : 114-123, 2004
12 Kim SG, "Multicenter retrospective clinical study of Osstem USII implant system in complete edentulous patients" 11 : 12-21, 2007
13 Kondo T, "Low-intensity ultra- sound adjuvant therapy:enhancement of doxorubicin indu- ced cytotoxicity and the acoustic mechanisms involved" 36 : 61-68, 2009
14 Romeo E, "Long-term survival and success of oral implants in the treatment of full and partial arches : a 7-year prospective study with the ITI dental implant system" 19 : 247-259, 2004
15 Tuner J, "Laser therapy, Clinical Practice and Scientific Background; A guide for research scientists, doctors, dentists, veterianarians and other interested parties within the medical field" Prima Books AB 2-60, 2002
16 Sawai Y, "Koto K : Effects of low-intensity pulsed ultrasound on osteosarcoma and cancer cells" 28 : 481-486, 2012
17 Wennstro¨m JL, "Implant-supported single-tooth restorations : a 5-year prospec-tive study" 32 : 567-574, 2005
18 Pounder NM, "Harrison AJ : Low intensity pulsed ultrasound for fracture healing : a review of the clinical evidence and the associated biological mechanism of action" 48 : 330-338, 2008
19 Bergman B, "Evaluation of the results of treatment with osseointegrated implants by the Swedish National Board of Health and Welfare" 50 : 114-115, 1983
20 황영섭 ; 전현준 ; 신상훈 ; 정인교 ; 김규천 ; 김철훈 ; 김욱규, "Effect of low intensity pulsed ultrasound (LIPUS) on bone healing around a titanium implant in the tibia of osteoporosis-induced rats" 37 : 386-395, 2011
21 Albrektsson T, "Consensus report of session IV" Quintessence 365-369, 1993
22 김영석 ; 이동근 ; 민승기 ; 이준 ; 문철, "Clini-cal study on success rate of osseointegrated dental implants" 24 : 137-147, 2002
23 Esposito M, "Biological factors contributing to failures of os-seointegrated oral implants. (I). Success criteria and epidemiology" 106 : 527-551, 1998
24 Esposito M, "A 5-year follow-up compara-tive analysis of the efficacy of various osseointe-grated dental implant systems : a systematic review of randomized controlled clinical trials" 20 : 557-568, 2005
25 Adell R, "A 15-year study of osseointegrated implants in the reatment of the edentulous jaw" 10 : 387-416, 1981
Power Supply System Configuration for Preventing Corrosion on Pipeline using a Low-cost SMPS Chip
A Study on Active Balancing Methods by Battery Stack Power Recovery
소방공무원의 직무만족이 이직의도에 미치는 영향: 직무내용의 조절효과를 중심으로