<P>This study aims to evaluate the potential jaw‐tracking advantage using control point sequences of volume volumetric‐modulated arc therapy (VMAT) planning. VMAT plans for patients with prostate and head and neck (H&N) cancers...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107538302
Kim, Jung‐ ; in ; Park, Jong Min ; Park, So‐ ; Yeon ; Choi, Chang Heon ; Wu, Hong‐ ; Gyun ; Ye, Sung‐ ; Joon
2014
-
SCOPUS,SCIE
학술저널
160-168(9쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>This study aims to evaluate the potential jaw‐tracking advantage using control point sequences of volume volumetric‐modulated arc therapy (VMAT) planning. VMAT plans for patients with prostate and head and neck (H&N) cancers...
<P>This study aims to evaluate the potential jaw‐tracking advantage using control point sequences of volume volumetric‐modulated arc therapy (VMAT) planning. VMAT plans for patients with prostate and head and neck (H&N) cancers were converted into new static arc (SA) plans. The SA plan consisted of a series of static fields at each control point of the VMAT plan. All other machine parameters of the SA plan were perfectly identical to those of the original VMAT plan. The jaw‐tracking static arc (JTSA) plans were generated with fields that closed the jaws of each SA field into the multileaf collimators (MLCs) aperture. The dosimetric advantages of JTSA over SA were evaluated in terms of a dose‐volume histogram (DVH) of organ at risk (OAR) after renormalizing both plans to make the same target coverage. Both plans were delivered to the MatriXX‐based COMPASS system for 3D volume dose verification. The average jaw size reduction of the JTSA along the X direction was 3.1±0.9 cm for prostate patients and 6.9±1.9 cm for H&N patients. For prostate patients, the organs far from the target showed larger sparing (3.7%—8.1% on aver‐age) in JTSA than the organs adjacent to the target (1.1%—1.5%). For the H&N plans, the mean dose reductions for all organs ranged from 4.3% to 11.9%. The dose reductions were more significant in the dose regions of <SUB>D80</SUB>,<SUB>D90</SUB>, and <SUB>D95</SUB> than the dose regions of <SUB>D5</SUB>,<SUB>D10</SUB>, and <SUB>D20</SUB> for all patients. Likewise, the deliverability and reproducibility of jaw‐tracking plan were validated. The measured dosimetric advantage of JTSA over SA coincided with the calculated one above.</P><P>PACS numbers: 87.55.D‐, 87.55.ne</P>
Improving image accuracy of region‐of‐interest in cone‐beam CT using prior image