RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      산지별 천연가스의 화염 안정영역에 관한 실험적 연구 = Experimental Study on the Flame Stable Region of Natural Gases from Various Producing Districts

      한글로보기

      https://www.riss.kr/link?id=A76506974

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In this study, the difference of flame stability zone for natural gases from producing districts was studied experimentally using a new type of flame stability diagram. The similarity of stable flame zone between a domestic appliance and an interchangeability test (IT) burner is also examined. As a result, the stable flame zones expressed by limits curves of flame lifting and yellow tipping show the similar results in a domestic gas range and IT burner. Furthermore, IT burner can reproduce the flash back phenomena and show the distinct difference of fuel type as the burner diameter is increased. To suggest the new type of flame stability diagram in the respect of fuel interchangeability, the air flowrate and Wobbe fuel flowrate were adopted as axis coordinates. It can be identified that the new diagram can provide the useful information on the difference of flame stability zone, heat input rate and air-fuel ratio when a fuel is altered to other fuels under the identical operating conditions. Finally, the stable flame zones for natural gas of 6 type are compared, and the detailed information to use as the interchangeability fuels of standard natural gas is provided using the new type of flame stability diagram.
      번역하기

      In this study, the difference of flame stability zone for natural gases from producing districts was studied experimentally using a new type of flame stability diagram. The similarity of stable flame zone between a domestic appliance and an interchang...

      In this study, the difference of flame stability zone for natural gases from producing districts was studied experimentally using a new type of flame stability diagram. The similarity of stable flame zone between a domestic appliance and an interchangeability test (IT) burner is also examined. As a result, the stable flame zones expressed by limits curves of flame lifting and yellow tipping show the similar results in a domestic gas range and IT burner. Furthermore, IT burner can reproduce the flash back phenomena and show the distinct difference of fuel type as the burner diameter is increased. To suggest the new type of flame stability diagram in the respect of fuel interchangeability, the air flowrate and Wobbe fuel flowrate were adopted as axis coordinates. It can be identified that the new diagram can provide the useful information on the difference of flame stability zone, heat input rate and air-fuel ratio when a fuel is altered to other fuels under the identical operating conditions. Finally, the stable flame zones for natural gas of 6 type are compared, and the detailed information to use as the interchangeability fuels of standard natural gas is provided using the new type of flame stability diagram.

      더보기

      목차 (Table of Contents)

      • ABSTRACT
      • 1. 서론
      • 2. 실험 장치 및 방법
      • 3. 실험 결과
      • 4. 결론
      • ABSTRACT
      • 1. 서론
      • 2. 실험 장치 및 방법
      • 3. 실험 결과
      • 4. 결론
      • 후기
      • 참고문헌
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼