      Evaluation of Patient Radiation Dose in Cardiovascular Interventional Procedures Using Monte Carlo Simulation

      한글로보기

      https://www.riss.kr/link?id=A109470231

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      The International Commission on Radiological Protection (ICRP) has established diagnostic reference levels (DRLs), which set benchmarks for limiting electromagnetic radiation doses across various procedures. This study reviewed DRLs based on dose report data for cardiovascular interventional procedures and analyzed patient electromagnetic radiation doses using Monte Carlo simulations and the High-Definition Reference Korean model, which is utilized as the voxel phantom. The procedures examined include coronary angiography (CAG), percutaneous coronary intervention (PCI), and percutaneous transluminal coronary angioplasty (PTCA). The diagnostic X-ray energy spectrum was generated using the SRS-78 program. Based on dose reports, the irradiation field was set to 13 × 13 cm², with tube voltages of 80 kVp, 100 kVp, and 120 kVp and exposure times of 243 seconds, 1043 seconds, and 1423 seconds, respectively. The source-to-image and source-to-skin distances were set to 120 cm and 84 cm, respectively. The NDD(K) method, an indirect dose calculation technique, was used to perform dose calculations and estimate absorbed doses across various organs. Subsequently, effective doses were calculated in accordance with the recommendations set in ICRP 60 and ICRP 103. The effective doses for CAG at 80 kVp and 100 kVp were found to be 1.47 mSv and 3.34 mSv, respectively. In PCI, the effective doses at 80 kVp, 100 kVp, and 120 kVp were 14.70 mSv, 9.52 mSv, and 16.00 mSv, respectively. For PTCA, the effective doses at 80 kVp, 100 kVp, and 120 kVp were observed to be 9.95 mSv, 24.16 mSv, and 32.83 mSv, respectively. Following the guidelines in ICRP 60 and ICRP 103, the conversion factors for effective dose ranged from 0.202 mSv/Gy·cm² to 0.418 mSv/Gy·cm² and from 0.213 mSv/Gy·cm² to 0.443 mSv/Gy·cm², respectively. These findings are expected to contribute to establishing optimal electromagnetic radiation exposure limits, promoting the safe management of medical electromagnetic radiation, and preventing excessive radiation exposure.
      번역하기

      The International Commission on Radiological Protection (ICRP) has established diagnostic reference levels (DRLs), which set benchmarks for limiting electromagnetic radiation doses across various procedures. This study reviewed DRLs based on dose repo...

      The International Commission on Radiological Protection (ICRP) has established diagnostic reference levels (DRLs), which set benchmarks for limiting electromagnetic radiation doses across various procedures. This study reviewed DRLs based on dose report data for cardiovascular interventional procedures and analyzed patient electromagnetic radiation doses using Monte Carlo simulations and the High-Definition Reference Korean model, which is utilized as the voxel phantom. The procedures examined include coronary angiography (CAG), percutaneous coronary intervention (PCI), and percutaneous transluminal coronary angioplasty (PTCA). The diagnostic X-ray energy spectrum was generated using the SRS-78 program. Based on dose reports, the irradiation field was set to 13 × 13 cm², with tube voltages of 80 kVp, 100 kVp, and 120 kVp and exposure times of 243 seconds, 1043 seconds, and 1423 seconds, respectively. The source-to-image and source-to-skin distances were set to 120 cm and 84 cm, respectively. The NDD(K) method, an indirect dose calculation technique, was used to perform dose calculations and estimate absorbed doses across various organs. Subsequently, effective doses were calculated in accordance with the recommendations set in ICRP 60 and ICRP 103. The effective doses for CAG at 80 kVp and 100 kVp were found to be 1.47 mSv and 3.34 mSv, respectively. In PCI, the effective doses at 80 kVp, 100 kVp, and 120 kVp were 14.70 mSv, 9.52 mSv, and 16.00 mSv, respectively. For PTCA, the effective doses at 80 kVp, 100 kVp, and 120 kVp were observed to be 9.95 mSv, 24.16 mSv, and 32.83 mSv, respectively. Following the guidelines in ICRP 60 and ICRP 103, the conversion factors for effective dose ranged from 0.202 mSv/Gy·cm² to 0.418 mSv/Gy·cm² and from 0.213 mSv/Gy·cm² to 0.443 mSv/Gy·cm², respectively. These findings are expected to contribute to establishing optimal electromagnetic radiation exposure limits, promoting the safe management of medical electromagnetic radiation, and preventing excessive radiation exposure.

      더보기

      참고문헌 (Reference)

      1 Y. H. Roh, 18 : 8097-, 2021

      2 E. Bogaert, 129 : 77-, 2008

      3 C. Lee, 55 : 339-, 2010

      4 N. Buls, 75 : 435-, 2002

      5 D. L. Miller, 257 : 321-, 2010

      6 P. Rauch, 39 : 2826-, 2012

      7 O. W. Linton, 181 : 321-, 2003

      8 J. A. Lepold, 130 : 29-, 2020

      9 J. S. Berger, 55 : 1169-, 2010

      10 J. W. Hirshfeld Jr., 71 : 2829-, 2018

      1 Y. H. Roh, 18 : 8097-, 2021

      2 E. Bogaert, 129 : 77-, 2008

      3 C. Lee, 55 : 339-, 2010

      4 N. Buls, 75 : 435-, 2002

      5 D. L. Miller, 257 : 321-, 2010

      6 P. Rauch, 39 : 2826-, 2012

      7 O. W. Linton, 181 : 321-, 2003

      8 J. A. Lepold, 130 : 29-, 2020

      9 J. S. Berger, 55 : 1169-, 2010

      10 J. W. Hirshfeld Jr., 71 : 2829-, 2018

      11 S. Nakamura, 31 : 655-, 2016

      12 E. Kuon, 76 : 906-, 2003

      13 M. Bhar, 82 : 200-, 2021

      14 E. T. Samara, 1 : 103-, 2012

      15 M. Portugal, 198 : 110253-, 2022

      16 C. H. Kim, 53 : 4093-, 2008

      17 Y. S. Yeom, 59 : 3969-, 2014

      18 M. J. Kim, "Study on measures to secure accuracy of dosimetric indications of diagnostic X-ray equipment" 2018

      19 K. Cranley, "Report 78: Catalogue of Diagnostic X-Ray Spectra and Other Data" IPEM 1997

      20 M. Roser, "Number of deaths from cardiovascular diseases, Our World in Data"

      21 E. Vañó, "ICRP publication 135: diagnostic reference levels in medical imaging" 46 : 71-76, 2017

      22 Institute for Health Metrics and Evaluation (IHME), "Global trends in age-standardised cardiovascular disease death rate" 2020

      23 World Health Organization, "Cardiovascular diseases (CVDs)"

      24 International Commission on Radiological Protection(ICRP), "Adult Reference Computational Phantoms" 110 : 2-, 2009

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼