RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

      한글로보기

      https://www.riss.kr/link?id=A108797997

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESIMS/ MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column (150 mm × 2.0 mm, 4 μm) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/ v) at a flow rate of 450 μL/min. Porphyrins and the internal standard (IS), coproporphyrin I-15N4, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.
      번역하기

      A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESIMS/ MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylpo...

      A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESIMS/ MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column (150 mm × 2.0 mm, 4 μm) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/ v) at a flow rate of 450 μL/min. Porphyrins and the internal standard (IS), coproporphyrin I-15N4, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼