    파형강판 이글루탄약고 결로 감소 방안 연구 = 63평형 탄약고를 중심으로

    한글로보기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Igloo-shaped ammunition depots made of corrugated steel plate has a higher risk of condensation since the change in inside heat capacity is greater and its thermal conduction rate is higher compared to existing concrete ammunition igloos. Therefore, measures to prevent condensation are necessary. We suggested a method to create air gaps of 30cm in width in the back and on both sides of an igloo, as we thought that creating air gaps on the bottom of an igloo would be expensive and difficult for construction. In this method, natural ventilation is designed so that air in the gaps is replaced by air outside the igloo. This ventilation technique will enhance the thermal function and allow the igloo to better resist, avoid, or expel geothermal heat. And we conducted a simulation by maintaining the depth of an igloo at the current 27m and creating air gaps of 30㎝ in width and 2m in height surrounding the side walls. The result found that the occurrence rate of condensation declined 20% under the condition of dead calm. Finally, we conducted a simulation by creating air gaps of 50cm in width and 2m in height surrounding the side walls. The result found that the occurrence rate further declined by 40%.
    번역하기

    Igloo-shaped ammunition depots made of corrugated steel plate has a higher risk of condensation since the change in inside heat capacity is greater and its thermal conduction rate is higher compared to existing concrete ammunition igloos. Therefore, m...

    Igloo-shaped ammunition depots made of corrugated steel plate has a higher risk of condensation since the change in inside heat capacity is greater and its thermal conduction rate is higher compared to existing concrete ammunition igloos. Therefore, measures to prevent condensation are necessary. We suggested a method to create air gaps of 30cm in width in the back and on both sides of an igloo, as we thought that creating air gaps on the bottom of an igloo would be expensive and difficult for construction. In this method, natural ventilation is designed so that air in the gaps is replaced by air outside the igloo. This ventilation technique will enhance the thermal function and allow the igloo to better resist, avoid, or expel geothermal heat. And we conducted a simulation by maintaining the depth of an igloo at the current 27m and creating air gaps of 30㎝ in width and 2m in height surrounding the side walls. The result found that the occurrence rate of condensation declined 20% under the condition of dead calm. Finally, we conducted a simulation by creating air gaps of 50cm in width and 2m in height surrounding the side walls. The result found that the occurrence rate further declined by 40%.

    더보기

    목차 (Table of Contents)

    • Abstract
    • 1. 서론
    • 2. 파형강판 이글루탄약고의 특징 분석
    • 3. 파형강판 이글루탄약고의 결로 발생 현상 분석
    • 4. 파형강판 이글루탄약고의 결로 감소 방안
    • Abstract
    • 1. 서론
    • 2. 파형강판 이글루탄약고의 특징 분석
    • 3. 파형강판 이글루탄약고의 결로 발생 현상 분석
    • 4. 파형강판 이글루탄약고의 결로 감소 방안
    • 5. 결론
    • 참고문헌